Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Commercial Building
Address NEW:
1507 W SAINT MARYS RD
Apply Date:
02/13/2025
Applicant:
Bryan Morris
Description:
New laundromat T.I. of existing 975 s.f. vacant space. Expansion of existing neighboring laundromat tenant (1507) by removal of demising wall between spaces. Plumbing, Mechanical and Electrical modifications included.

Permit Reviews

Permit Number - TC-COM-0225-00318
Permit Status: Inspections
Permit Description: New laundromat T.I. of existing 975 s.f. vacant space. Expansion of existing neighboring laundromat tenant (1507) by removal of demising wall between spaces. Plumbing, Mechanical and Electrical modifications included.
Start Date Submittal Complete Date Status  
05/19/2025 COMMERCIAL REVIEW - FULL v.2 05/19/2025 REQUIRES RESUBMIT Review Details
08/08/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/12/2025 APPROVED Review Details
02/18/2025 COMMERCIAL REVIEW - FULL v.1 03/17/2025 REQUIRES RESUBMIT Review Details
07/14/2025 COMMERCIAL REVIEW - FULL v.3 08/01/2025 APPROVED Review Details
08/01/2025 RESTAMP - COMMERCIAL v.1 08/04/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0225-00318
Permit Status: Inspections
Permit Description: New laundromat T.I. of existing 975 s.f. vacant space. Expansion of existing neighboring laundromat tenant (1507) by removal of demising wall between spaces. Plumbing, Mechanical and Electrical modifications included.
Total Outstanding Activity Conditions - 3
Date Name
03/11/2025 WATER STERILIZATION REPORT IS REQUIRED.
07/15/2025 AIR BALANCING REPORT IS REQUIRED.
08/01/2025 Special Inspection for the Titen Screw Anchors for the Steel Angle Lintel at the Existing Bearing Masonry Wall

Conditions

Permit Number - TC-COM-0225-00318
Permit Status: Inspections
Permit Description: New laundromat T.I. of existing 975 s.f. vacant space. Expansion of existing neighboring laundromat tenant (1507) by removal of demising wall between spaces. Plumbing, Mechanical and Electrical modifications included.
Date Description Comments
02/18/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
02/18/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
07/31/2025 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0225-00318
Permite Description: New laundromat T.I. of existing 975 s.f. vacant space. Expansion of existing neighboring laundromat tenant (1507) by removal of demising wall between spaces. Plumbing, Mechanical and Electrical modifications included.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/14/2025 COT - LCPL - Plumbing Intermediate N/A Partial Pass Plumbing underground for 2” waste line. Ok to,cover progress area.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-0225-00318
Permit Description: New laundromat T.I. of existing 975 s.f. vacant space. Expansion of existing neighboring laundromat tenant (1507) by removal of demising wall between spaces. Plumbing, Mechanical and Electrical modifications included.
Total Completed Inspections - 12
Date Description Inspector Results Comments
10/17/2025 COT - LCBU - Framing Passed Ok to one side sheet rock.
10/22/2025 COT - LCEL - Electrical Intermediate Passed In wall electric complete; Ok to insulate progress areas and sheet rock.
10/29/2025 COT - LCPL - Gas Pressure Test Passed New gas lines connected to existing gas lines: no new meter required.
11/06/2025 BULD - Electrical Clearance Passed Clearance for TEP RECN. 11/6/2025
11/06/2025 COT - LCME - Mechanical Intermediate Passed
11/06/2025 COT - LCEL - Electrical Above Ceiling Passed
11/06/2025 COT - FCON - Sprinkler - Final Passed
11/17/2025 COT - FCON - Fire - Final Passed
11/17/2025 COT - LCPL - Plumbing Intermediate Passed
11/17/2025 COT - LCEL - Electrical Final Passed
11/17/2025 COT - LCME - Mechanical Final Passed
11/17/2025 COT - LCPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
SPECIAL_INSP. CERT. TC-COM-0225-00318_SEALED_V1.PDF DOCUMENTS VIEW
CONS-COINLESS LAUNDRY_ST MARYS PH2_COMPLETE SET_V2.PDF DOCUMENTS VIEW
STRUCT. CALCULATIONS TC-COM-0225-00318_V1.PDF DOCUMENTS VIEW
C10-25-05 DECISION.PDF DOCUMENTS VIEW
C10-25-05 STAFF REPORT.PDF DOCUMENTS VIEW
C10-25-05 NOTICE.PDF SPECIAL APPLICATIONS VIEW
C10-25-05 APPLICATION.PDF SPECIAL APPLICATIONS VIEW
C10-25-05 PLAN SET.PDF SPECIAL APPLICATIONS VIEW