Permit: TC-COM-0224-00305
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
1215 E PENNSYLVANIA ST
Address NEW:
1215 E PENNSYLVANIA ST
Apply Date:
02/15/2024
Applicant:
Al Buck
Description:
This shall be a remodeling of an existing 1 story slab-on-grade building to build out a data hall in an Electronic Data Storage Center and attached Office component. The exterior walls are existing precast concrete panels and shall remain. The roof is a low slope membrane roof on metal deck and bar joist Any new interior wall shall be metal studs and gypsum board construction.
Permit Reviews
Permit Number - TC-COM-0224-00305
Permit Status: Inspections
Permit Description: This shall be a remodeling of an existing 1 story slab-on-grade building to build out a data hall in an Electronic Data Storage Center and attached Office component. The exterior walls are existing precast concrete panels and shall remain. The roof is a low slope membrane roof on metal deck and bar joist Any new interior wall shall be metal studs and gypsum board construction.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/24/2024 | RESTAMP - COMMERCIAL v.1 | 05/24/2024 | APPROVED |
| 06/03/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/04/2024 | APPROVED |
| 02/16/2024 | COMMERCIAL REVIEW - FULL v.1 | 03/19/2024 | REQUIRES RESUBMIT |
| 12/19/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 12/20/2024 | APPROVED |
| 04/05/2024 | COMMERCIAL REVIEW - FULL v.2 | 05/24/2024 | APPROVED |
Conditions
Permit Number - TC-COM-0224-00305
Permit Status: Inspections
Permit Description: This shall be a remodeling of an existing 1 story slab-on-grade building to build out a data hall in an Electronic Data Storage Center and attached Office component. The exterior walls are existing precast concrete panels and shall remain. The roof is a low slope membrane roof on metal deck and bar joist Any new interior wall shall be metal studs and gypsum board construction.
| Date | Description | Comments |
|---|---|---|
| 02/16/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 05/24/2024 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. | |
| 05/24/2024 | SPECIAL INSPECTION FOR WELDING IS REQUIRED. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0224-00305
Permite Description: This shall be a remodeling of an existing 1 story slab-on-grade building to build out a data hall in an Electronic Data Storage Center and attached Office component. The exterior walls are existing precast concrete panels and shall remain. The roof is a low slope membrane roof on metal deck and bar joist Any new interior wall shall be metal studs and gypsum board construction.
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2024 | COT - HCBU - Framing | N/A | Partial Pass | 9/23/24: Framing at future data hall c complete ok to one-side, framing at data hall b partial pass pending southwest corner. Mechanical room framing passed. battery room A and B per plan. |
| 02/14/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 02/14/2025 | COT - FCON - Fire - Final | N/A | Partial Pass | Emergency lights shall be repaired. |
| 02/14/2025 | BULD - Electrical Clearance | N/A | Not Applicable |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0224-00305
Permit Description: This shall be a remodeling of an existing 1 story slab-on-grade building to build out a data hall in an Electronic Data Storage Center and attached Office component. The exterior walls are existing precast concrete panels and shall remain. The roof is a low slope membrane roof on metal deck and bar joist Any new interior wall shall be metal studs and gypsum board construction.
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2024 | COT - HCBU - Framing | Passed | Data hall B, pump room framing approved. Two exit lights and two regular lighting in pump room area approved. Okay to proceed progress areas. 10/2/2024 | |
| 02/06/2025 | COT - HCBU - Building Final | Passed | ||
| 02/06/2025 | COT - HCEL - Electrical Final | Passed | ||
| 02/06/2025 | COT - HCME - Mechanical Final | Passed | ||
| 02/06/2025 | COT - HCBU - CofO | Passed | OK to make application for Certificate of Occupancy. | |
| 02/06/2025 | COT - HCPL - Plumbing Final | Passed | ||
| 02/14/2025 | COT - FCON - Alarm - Final | Passed | Approved on 2/5/25 on permit TF-FCP-1224-01054 | |
| 02/14/2025 | ENGR Engineering Final | Passed | ||
| 02/14/2025 | TRSP - ROW - Final/Close-Out | Passed | ||
| 02/14/2025 | COT - FCON - Sprinkler - Final | Passed | Approved on 2/5/25 on permit TF-FCP-0824-00642 | |
| 02/14/2025 | COT - HCEL - Electrical Underground | Passed | ||
| 02/14/2025 | COT - HCBU - Building Progress | Passed | ||
| 02/14/2025 | COT - HCEL - Electrical Intermediate | Passed | ||
| 02/14/2025 | COT - HCBU - Building Above Ceiling | Passed | ||
| 02/14/2025 | COT - HCEL - Electrical Above Ceiling | Passed | ||
| 02/14/2025 | COT - HCEL - Electrical Progress | Passed | ||
| 02/14/2025 | COT - HCME - Mechanical Above Ceiling | Passed | ||
| 02/14/2025 | COT - HCME - Mechanical Intermediate | Passed | ||
| 02/14/2025 | COT - HCME - Mechanical Progress | Passed | ||
| 02/15/2025 | COT - HCPL - Plumbing Above Ceiling | Passed | ||
| 02/14/2025 | COT - HCPL - Plumbing Intermediate | Passed | ||
| 02/14/2025 | COT - HCPL - Plumbing Progress | Passed |