Permit: TC-COM-0126-00142
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
30 E CAMINO VILLAS UNIT 206
Address NEW:
30 E CAMINO VILLAS UNIT 206
Apply Date:
01/30/2026
Applicant:
OSTES HERNANDEZ
Description:
Need to repair/replace bussing from meter to main breaker in MULTIMETER pack. Emergency as this unit is without power. NO conductors are being changed. Existing SES is a multimeter pack rated at 800A. Individual meters/main breakers are rated at 100A. The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A.
Permit Reviews
Permit Number - TC-COM-0126-00142
Permit Status: Complete
Permit Description: Need to repair/replace bussing from meter to main breaker in MULTIMETER pack.
Emergency as this unit is without power.
NO conductors are being changed.
Existing SES is a multimeter pack rated at 800A.
Individual meters/main breakers are rated at 100A.
The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2026 | COMMERCIAL PDSD SIMPLE REVIEW v.1 | 01/30/2026 | REQUIRES RESUBMIT |
| 02/03/2026 | COMMERCIAL PDSD SIMPLE REVIEW v.2 | 02/03/2026 | APPROVED |
Conditions
Permit Number - TC-COM-0126-00142
Permit Status: Complete
Permit Description: Need to repair/replace bussing from meter to main breaker in MULTIMETER pack.
Emergency as this unit is without power.
NO conductors are being changed.
Existing SES is a multimeter pack rated at 800A.
Individual meters/main breakers are rated at 100A.
The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A.
| Date | Description | Comments |
|---|---|---|
| 01/30/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0126-00142
Permit Description: Need to repair/replace bussing from meter to main breaker in MULTIMETER pack.
Emergency as this unit is without power.
NO conductors are being changed.
Existing SES is a multimeter pack rated at 800A.
Individual meters/main breakers are rated at 100A.
The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/09/2026 | BULD - Electrical Clearance | Passed | ||
| 02/13/2026 | COT - LCEL - Electrical Final | Passed |