Permit Details

Status:
Complete
Type:
Commercial Building
Address:
244 E GRANT RD
Address NEW:
244 E GRANT RD
Apply Date:
01/03/2026
Applicant:
James Lynch
Description:
1. Provide qualified electricians to install materials and perform labor per all NEC, NFPA70E and OSHA standards. 2. Provide and install (2) additional neutral wires from existing panel to existing power post location near break tent to convert existing two pole 30A circuit into two single phase 20A circuits. 3. Provide and install (1) new circuit in existing raceway from existing panel to existing power post location near break tent to add a fourth dedicated circuit to this location. Add two additional duplex receptacles and a bubble cover. one duplex receptacle per circuit. 4. Provide and install (1) additional circuit in existing raceway from existing panel to existing power post location near shower trailer. Install (1) NEX outdoor rated box with two duplex receptacles and bubble cover. 5. Provide and install (2) new quad receptacle boxes next to panel, each with a dedicated circuit and bubble cover for charging station and future use. 6. Energize and power check all new install. 7. Perform all work in a safe, neat and workman like manner.

Permit Reviews

Permit Number - TC-COM-0126-00002
Permit Status: Complete
Permit Description: 1. Provide qualified electricians to install materials and perform labor per all NEC, NFPA70E and OSHA standards. 2. Provide and install (2) additional neutral wires from existing panel to existing power post location near break tent to convert existing two pole 30A circuit into two single phase 20A circuits. 3. Provide and install (1) new circuit in existing raceway from existing panel to existing power post location near break tent to add a fourth dedicated circuit to this location. Add two additional duplex receptacles and a bubble cover. one duplex receptacle per circuit. 4. Provide and install (1) additional circuit in existing raceway from existing panel to existing power post location near shower trailer. Install (1) NEX outdoor rated box with two duplex receptacles and bubble cover. 5. Provide and install (2) new quad receptacle boxes next to panel, each with a dedicated circuit and bubble cover for charging station and future use. 6. Energize and power check all new install. 7. Perform all work in a safe, neat and workman like manner.
Start Date Submittal Complete Date Status  
02/02/2026 COMMERCIAL PDSD SIMPLE REVIEW v.2 02/03/2026 APPROVED Review Details
01/05/2026 COMMERCIAL PDSD SIMPLE REVIEW v.1 01/05/2026 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-0126-00002
Permit Status: Complete
Permit Description: 1. Provide qualified electricians to install materials and perform labor per all NEC, NFPA70E and OSHA standards. 2. Provide and install (2) additional neutral wires from existing panel to existing power post location near break tent to convert existing two pole 30A circuit into two single phase 20A circuits. 3. Provide and install (1) new circuit in existing raceway from existing panel to existing power post location near break tent to add a fourth dedicated circuit to this location. Add two additional duplex receptacles and a bubble cover. one duplex receptacle per circuit. 4. Provide and install (1) additional circuit in existing raceway from existing panel to existing power post location near shower trailer. Install (1) NEX outdoor rated box with two duplex receptacles and bubble cover. 5. Provide and install (2) new quad receptacle boxes next to panel, each with a dedicated circuit and bubble cover for charging station and future use. 6. Energize and power check all new install. 7. Perform all work in a safe, neat and workman like manner.
Date Description Comments
01/05/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-0126-00002
Permit Description: 1. Provide qualified electricians to install materials and perform labor per all NEC, NFPA70E and OSHA standards. 2. Provide and install (2) additional neutral wires from existing panel to existing power post location near break tent to convert existing two pole 30A circuit into two single phase 20A circuits. 3. Provide and install (1) new circuit in existing raceway from existing panel to existing power post location near break tent to add a fourth dedicated circuit to this location. Add two additional duplex receptacles and a bubble cover. one duplex receptacle per circuit. 4. Provide and install (1) additional circuit in existing raceway from existing panel to existing power post location near shower trailer. Install (1) NEX outdoor rated box with two duplex receptacles and bubble cover. 5. Provide and install (2) new quad receptacle boxes next to panel, each with a dedicated circuit and bubble cover for charging station and future use. 6. Energize and power check all new install. 7. Perform all work in a safe, neat and workman like manner.
Total Completed Inspections - 3
Date Description Inspector Results Comments
02/13/2026 COT - LCEL - Electrical Intermediate Passed
02/13/2026 COT - LCEL - Electrical Underground Passed
02/17/2026 COT - LCEL - Electrical Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
10.6.25 SITE PLAN_V2.PDF DOCUMENTS VIEW
ES1.0 SEALED_V1.PDF DOCUMENTS VIEW