Permit Details

Status:
Complete
Type:
Commercial Building
Address NEW:
6252 E SPEEDWAY BL
Apply Date:
01/05/2024
Applicant:
Erick Erives
Description:
REPAIR ROOF, REPLACE EXT'G ROOFTOP A/C , REPLACE PANEL C

Permit Reviews

Permit Number - TC-COM-0124-00027
Permit Status: Complete
Permit Description: REPAIR ROOF, REPLACE EXT'G ROOFTOP A/C , REPLACE PANEL C
Start Date Submittal Complete Date Status  
04/18/2024 RESTAMP - COMMERCIAL v.1 04/22/2024 APPROVED Review Details
01/05/2024 COMMERCIAL REVIEW - FULL v.1 02/05/2024 REQUIRES RESUBMIT Review Details
08/26/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/27/2024 APPROVED Review Details
03/06/2024 COMMERCIAL REVIEW - FULL v.2 04/08/2024 REQUIRES RESUBMIT Review Details
06/26/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/27/2024 APPROVED Review Details
04/12/2024 COMMERCIAL REVIEW - FULL v.3 04/18/2024 APPROVED Review Details
08/09/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/14/2024 APPROVED Review Details

Conditions

Permit Number - TC-COM-0124-00027
Permit Status: Complete
Permit Description: REPAIR ROOF, REPLACE EXT'G ROOFTOP A/C , REPLACE PANEL C
Date Description Comments
02/01/2024 AIR BALANCING REPORT IS REQUIRED.
01/05/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
06/27/2024 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
06/27/2024
06/27/2024 Post-Installed Anchor Inspection Report is required.
06/27/2024 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
02/02/2024 SPECIAL INSPECTION FOR Roof Framing Over Existing Roof IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-0124-00027
Permite Description: REPAIR ROOF, REPLACE EXT'G ROOFTOP A/C , REPLACE PANEL C
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
05/01/2024 COT - LCEL - Electrical Intermediate N/A Not Ready
06/27/2024 COT - LCPL - Plumbing Roof Drains N/A Not Applicable
06/27/2024 COT - LCEL - Electrical Above Ceiling N/A Not Applicable
05/01/2024 COT - LCME - Mechanical Intermediate N/A Not Ready Spoke with Eric about obtaining revision for structural footings/ post being installed.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-0124-00027
Permit Description: REPAIR ROOF, REPLACE EXT'G ROOFTOP A/C , REPLACE PANEL C
Total Completed Inspections - 9
Date Description Inspector Results Comments
04/30/2024 COT - LCBU - Roof Nailing Passed
04/30/2024 COT - LCBU - Framing Passed
05/15/2024 COT - FCON - Fire - Final Passed
06/27/2024 COT - LCEL - Electrical Intermediate Passed
06/27/2024 COT - LCPL - Plumbing Final Passed
06/27/2024 COT - LCME - Mechanical Intermediate Passed
06/28/2024 COT - LCBU - Building Final Passed
06/28/2024 COT - LCEL - Electrical Final Passed
06/28/2024 COT - LCME - Mechanical Final Passed