Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Apply Date:
01/09/2023
Applicant:
Bobbie Varnum
Description:
Commercial tenant improvement for restaurant

Permit Reviews

Permit Number - TC-COM-0123-00435
Permit Status: Complete
Permit Description: Commercial tenant improvement for restaurant
Start Date Submittal Complete Date Status  
11/14/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/15/2023 APPROVED Review Details
03/09/2023 COMMERCIAL REVIEW - FULL v.2 03/27/2023 REQUIRES RESUBMIT Review Details
05/17/2023 RESTAMP - COMMERCIAL v.1 05/19/2023 APPROVED Review Details
04/14/2023 COMMERCIAL REVIEW - FULL v.3 05/05/2023 REQUIRES RESUBMIT Review Details
05/16/2023 COMMERCIAL REVIEW - FULL v.4 05/17/2023 APPROVED Review Details
01/26/2023 COMMERCIAL REVIEW - FULL v.1 02/17/2023 REQUIRES RESUBMIT Review Details

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-0123-00435
Permite Description: Commercial tenant improvement for restaurant
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/04/2023 BULD - Electrical Clearance N/A Not Applicable
12/14/2023 COT - BULD - SWG Clearance N/A Not Applicable No gas service required for this suite.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-0123-00435
Permit Description: Commercial tenant improvement for restaurant
Total Completed Inspections - 12
Date Description Inspector Results Comments
06/09/2023 COT - LCBU - Framing Passed Ok to insulate and cover walls.
06/21/2023 COT - LCME - Mechanical Intermediate Passed Spiral duct system in place, registers to be added. Ok to cover ceiling areas.
08/22/2023 COT - HCEL - Electrical Above Ceiling Passed 8/22/23: Electrical above ceiling passed. Ok to cover drop ceiling
08/22/2023 COT - LCEL - Electrical Intermediate Passed 8/22/23: Electrical above ceiling passed. Ok to cover drop ceiling
09/07/2023 COT - LCPL - Plumbing Intermediate Passed 8/25/23: okay to backfill grease trap and underground plumbing associated with it existing gas will be covered with tracer wire attached

9/7/23: grease trap covers adjusted above finish grade for slab pour (all under ground plumbing clean outs have covers) ok to pour
10/16/2023 COT - FCON - Fire - Final Passed
12/14/2023 COT - LCBU - Building Final Passed
12/14/2023 COT - LCEL - Electrical Final Passed
12/14/2023 COT - LCME - Mechanical Final Passed
12/14/2023 COT - LCPL - Plumbing Final Passed
12/19/2023 COT - FCON - Alarm - Final Passed
12/19/2023 COT - FCON - Sprinkler - Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
7763 PERMIT TC-COM-0123-00435 CHLORINATION REPORT 11-9-2023-2023-11-13_V1.PDF DOCUMENTS VIEW
7763 PERMIT TC-COM-0123-00435 TAB REPORT 9-22-2023 SONORAN MOONSHINE - _V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-PLAN SET_V1.PDF DOCUMENTS VIEW
2_PLAN SET_V1.PDF DOCUMENTS VIEW
1_MECHANICAL_COMPLIANCE_CERT_V1.PDF DOCUMENTS VIEW
1_MECHANICAL_SYSTEM_DESIGN_REPORT_V1.PDF DOCUMENTS VIEW
2_REFERENCE-FULLBLDG-CODE_V1.PDF DOCUMENTS VIEW
2_RESPONSE LETTER_V1.PDF DOCUMENTS VIEW
CONS-1_PLAN SET_V1.PDF DOCUMENTS VIEW