Permit: T99PL00624
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2036 W PROBASCO DR
Address NEW:
2036 W PROBASCO DR
Apply Date:
03/19/1999
Applicant:
COM-PAC INC
Description:
WATER METER:RELOCATE
Contractors:
- COM-PAC INC
Outstanding Inspections
Permit Status: Expired
Permit Number: T99PL00624
Permite Description: WATER METER:RELOCATE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/1999 | PLUMBING - FINAL | N/A | Correction Required | ADDTL COMMS - 1. ELECT GROUNDING CONDUCTOR IS BONDED TO EXTERIOR GALV. HOSE BIBB. DI-ELECTRIC UNION REPLACED WITH A BRASS NIPPLE. |
Completed Inspections
Permit Status: Expired
Permit Number: T99PL00624
Permit Description: WATER METER:RELOCATE
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/1999 | PLUMBING - YARD WTR LINE/TEST | MTESTER | Approved | ADDTL COMMS - 1. (78) SEVENTY EIGHT FEET OF 1 P.V.C PIPING. 2. (5) FIVE FEET OF 3/4 COPPER. 3. CHANGE COPPER TO GALV JUNCTION TO EITHER A BRASS NIPPLE OR A DI-ELECTRIC UNION. |