Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
575 W WILLIAMS ST
Apply Date:
10/28/1999
Applicant:
CHICANOS POR LA CAUSA
Description:
SFR:TD#14-34-57

Completed Inspections

Permit Status: Final
Permit Number: T99CM05160
Permit Description: SFR:TD#14-34-57
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/22/1999 ROOF NAILING JRIVA Approved IVRS - Inspection 0999*
12/22/1999 ROOF NAILING JRIVA Approved ADDTL COMMS - 1. INCORRECT HOLD DOWNS AT CARPORT STORAGE-REQUIRES HPAHD 22 5 PAAD-42 INSTALLED. PROVIDE INGINEER AND C.O.T. APPROVED REPAIR. 3. 15/10 NOT COMPLIED WITH. 4. 12/10 NOT COMPLIED WITH. 5. ST 2115 STRAPS MISSING AT CARPORT. 5. ST 2115 STRAPS MISSING AT CARPORT. 12. RIPPERS LESS THAN 12 ON ROOF NOT ALLOWED UNLESS EDGES BLOCKED. NOTE: SHEAR WALL 4 REQUIRES SHEATHING TO ROOF DECK.
12/22/1999 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*
12/22/1999 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved ADDTL COMMS - 7. CLIP ALL BEARING STUDS TOP AND BOTTOM. NOT EVERY OTHER STUD. 8. 4 EACH PAHD 42 HOLD DOWNS MISSING OR IN WRONG LOCATIONS AT REAR OF HOUSE. PROVIDE ENGINEERS AND C.O.T. APPROVED REPAIR. 9. BEDROOM 2 REQUIRES 2X10 HEADER. 10. SHEAR WALL 2 REQUIRES BLOCKING. 11. CARPORT NOT PER 13/10 BUILD TO PLAN OR HAVE ARCHITECT REVISE PLAN AND HAVE APPROVED BY CITY OF TUCSON.