Permit: T99CM04997
Permit Details
Apply Date:
10/22/1999
Applicant:
LANTANA CORPORATION
Description:
TOWNHOUSE:TD#14-03-36
Contractors:
- LANTANA CORPORATION
Completed Inspections
Permit Status: Final
Permit Number: T99CM04997
Permit Description: TOWNHOUSE:TD#14-03-36
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/22/1999 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | ADDTL COMMS - 1. SOIL WATER TEST OK 2. OK TO BACKFILL IN BLDG ONLY 3. NOTE: REMOVE TWO WAY C.O. AND REPLACE WITH TWO 3 COMBOS FACING EACH OTHER FOR C.O. |
| 11/30/1999 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | ADDTL COMMS - 1. SOIL WATER TEST OK. 2. HCS CONNECTION OK. 3. MUST REMOVE 3 C.O. TEE @ HCS THERE CAN BE NO THREADED FITTINGS UNDERGROUND. 4. OK TO BACKFILL TRENCH. NOTE: LEAVE TEST TEE WITH KEN. |
| 03/20/2000 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. P-TAPE CAN NOT BE USED HAS HANGERS 3. GAS PRESSURE TEST OK 4. OVERHEAD WATER DISTRIBUTION OK 5. OK TO DRYWALL |
| 07/31/2000 | PERMIT FINALED | AMATHIES | Approved | |
| 07/31/2000 | SHEET ROCK NAILING | AMATHIES | Approved | |
| 07/31/2000 | ROOF NAILING | AMATHIES | Approved |