Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T99CM04794
Permit Details
Apply Date:
10/08/1999
Applicant:
SAYLER-BROWN, THOMAS
Description:
TI:KITCHEN FOR RESTAURANT
Architects:
- SAYLER-BROWN, THOMAS
Contractors:
- FU S CONSTRUCTION ,
Completed Inspections
Permit Status: C of o
Permit Number: T99CM04794
Permit Description: TI:KITCHEN FOR RESTAURANT
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/14/2000 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | ADDTL COMMS - 1. SOIL WATER TEST OK 2. OK TO BACKFILL TRENCH 3. WILL REQUIRE REVISED AND APPROVED DRAWING ON WASTE AND VENT SYSTEM BEFORE FINAL 1. SEE SECTION 1013.0,1011.9 UPC DISHWASHER AND WASTE DISPOSAL UNIT CAN BE CONNECTED TO OR DISCHARGE INTO ANY GREASE TRAP 2. HAND SINKS, MOP SINK ARE NOT GREASE CONVEYING DRAINS. DO NOT CONNECT INTO GREASE TRAP 3. WILL REQUIRE REVISED AND APPROVED DRAWING ON WASTE AND VENT SYSTEM BEFORE FINAL |
02/07/2000 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | ADDTL COMMS - 1. OVERHEAD WATER DISTRIBUTION OK 2. GREASE TRAP INTERCEPTOR INSTALLATION OK 3. OK TO BACKFILL TRENCH |
02/11/2000 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | ADDTL COMMS - 1. GAS PRESSURE TEST OK 2. WILL REQUIRE REVISED AND APPROVED DRAWING ON GAS LINE BEFORE FINAL |