Completed Inspections

Permit Status: Final
Permit Number: T99CM04702
Permit Description: TI:RESTAURANT
Total Completed Inspections - 9
Date Description Inspector Results Comments
11/03/1999 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection 0000*
11/23/1999 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection 0000*
12/09/1999 ELECTRIC - ABOVE CEILING RSUBA Approved PARTIAL APPROVAL
12/09/1999 ELECTRIC - ABOVE CEILING RSUBA Approved ADDTL COMMS - SOME J-BOXES ARE OVERFILLED SEE ART. 370 C.E.C. FOR ASSISTANCE
12/29/1999 FIRE - FINAL FIRE Approved DENIED
12/29/1999 BUILDING - FINAL DWITT Approved ADDTL COMMS - APPROVED AS ADMINISTRATIVE ADDRESS.
12/30/1999 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*
12/30/1999 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection 0000*
12/30/1999 ELECTRIC - FINAL RSUBA Approved ADDTL COMMS - 1. INSTALL HANDY BOX EXTENSION THROUGH COUNTER TOPS DO BRING FLUSH OR WITHIN 1/4 PER N.E.C. 2. SEAL ALL PENETRATIONS INTO WALKIN (INSIDE CONDUIT TOO) 3. FINISH WALK IN COOLERS WIRE TIME CLOCK WITH THE COVER ON AND TERMINATE ALL STRANDED CONDUCTORS USING STA CON TYPE CONNECTORS.