Status:
Final
Type:
DUPLEX NEW
Apply Date:
09/21/1999
Applicant:
MICHAELS WARREN W
Description:
DUPLEX

Permit Reviews

Permit Number - T99CM04515
Permit Status: Final
Permit Description: DUPLEX
Start Date Submittal Complete Date Status  
04/04/2001 REVISION 04/04/2001 COMPLETED Review Details
10/18/2000 REVISION 10/19/2000 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T99CM04515
Permit Description: DUPLEX
Total Completed Inspections - 21
Date Description Inspector Results Comments
06/06/2000 FRAMING RAIELLO Approved IVRS - Inspection 0000*
09/19/2000 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*
1. ABS SEWER OK
2. WATER TEST OK
3. OK TO COVER
09/19/2000 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*
1. PVC WATER PIPING OK
PRESSURE TEST OK
OK TO COVER
09/19/2000 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
1. WATER TEST OK
2. UNDERGROUND PIPING OK
3. MAKE PLAN REVISION REFLECTING AS BUILT INSTALLATION
4. OK TO COVER
09/22/2000 ELECTRIC - UFER JORTA Approved IVRS - Inspection 0000*
09/22/2000 BUILDING PRE-SLAB DWITT Approved IVRS - Inspection 0000*
09/22/2000 STEM WALL/RETAINING WALL DWITT Approved IVRS - Inspection 0000*
09/22/2000 EXCAVATION/LAYOUT REBAR & ZON DWITT Approved IVRS - Inspection 0000*
10/02/2000 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
ALL UNDERGROUND SCOTCH COAT NOW COMPLETE
PRESSURE TEST OK
OK TO COVER
NOTE I DON'T CARE FOR THE WAY YOU PARALLELED THE FOOTING WITH YOUR GAS TRENCH CHECK YOUR BLDG CODES
10/11/2000 ROOF NAILING DWITT Approved IVRS - Inspection 0000*
FIX SHINERS
PROVIDE NAILERS AT UNSUPPORTED EDGES AT VALLEYS
10/11/2000 EXT METAL CLIPS/EXT SHEATHING DWITT Approved IVRS - Inspection 0000*
BE CAREFUL WITH THE TEMPORARY PORCH POSTS
11/09/2000 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection 0000*
11/14/2000 STUCCO MESH DWITT Approved IVRS - Inspection 0000*
APPROVED FOR ONE COAT AS NOTED
STALE BOTH SIDES OF INSIDE CORNERS ON PORCHES NOT ONE STAPLE FOR BOTH SIDES
CAULK REFRIGERANT LINES, CONDENSATE ETC
FINISH THE TWO WINDOWS ON NORTHWALLS, EAST UNIT
BE CAREFUL DRAGGING HOSES AROUND THE TEMPORARY PORCH POSTS
11/15/2000 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
LOOKS GOOD
11/17/2000 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
IF CORRECTIONS HAVE BEEN MADE IN COMMON WALL OK TO COVER
DO NOT COVER KITCHEN WALLS UNTIL CORRECTIONS HAVE BEEN MADE AND INSPECTED
PLEASE HAVE INSPECTION REPORTS ON SITE FOR VERIFICATION OF CORRECTIONS
PLEASE HAVE "AS BUILT" GAS ISOMETRIC AND SIZING AVAILABLE AS PRINT DOES NOT REFLECT INSTALLATION
11/17/2000 ELECTRIC - CABLE DROP RMAJUTA Approved IVRS - Inspection 0000*
OK TO CLEAR CABLE DROPS FOR #2 &#3
NOTE: 2- ROMEX CONDUTORS IN THE AREA OF THE ACCESS PANEL IN WASH ROOM (EAST) NEED TO BE MOVED, THEY NEED TO BE OUT OF THE WAY FOR PEOPLE CLIMBING IN AND REMOVING COVER WILL CHECK ON FINAL
11/21/2000 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection 0000*
12/01/2000 SHEET ROCK NAILING AQUIROZ Approved EXCLUDES 1 HOUR WALL BETWEEN APPOINTMENT.
03/29/2001 BUILDING - FINAL DWITT Approved IVRS - Inspection 0000*
03/29/2001 U VALUE FOR WINDOW DWITT Approved
04/10/2001 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*

Documents

File Name Document Type  