Permit: T99CM04515
Permit Details
Apply Date:
09/21/1999
Applicant:
MICHAELS WARREN W
Description:
DUPLEX
Permit Reviews
Permit Number - T99CM04515
Permit Status: Final
Permit Description: DUPLEX
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/04/2001 | REVISION | 04/04/2001 | COMPLETED |
10/18/2000 | REVISION | 10/19/2000 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T99CM04515
Permit Description: DUPLEX
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/06/2000 | FRAMING | RAIELLO | Approved | IVRS - Inspection 0000* |
09/19/2000 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* 1. ABS SEWER OK 2. WATER TEST OK 3. OK TO COVER |
09/19/2000 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* 1. PVC WATER PIPING OK PRESSURE TEST OK OK TO COVER |
09/19/2000 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* 1. WATER TEST OK 2. UNDERGROUND PIPING OK 3. MAKE PLAN REVISION REFLECTING AS BUILT INSTALLATION 4. OK TO COVER |
09/22/2000 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* |
09/22/2000 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
09/22/2000 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* |
09/22/2000 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* |
10/02/2000 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* ALL UNDERGROUND SCOTCH COAT NOW COMPLETE PRESSURE TEST OK OK TO COVER NOTE I DON'T CARE FOR THE WAY YOU PARALLELED THE FOOTING WITH YOUR GAS TRENCH CHECK YOUR BLDG CODES |
10/11/2000 | ROOF NAILING | DWITT | Approved | IVRS - Inspection 0000* FIX SHINERS PROVIDE NAILERS AT UNSUPPORTED EDGES AT VALLEYS |
10/11/2000 | EXT METAL CLIPS/EXT SHEATHING | DWITT | Approved | IVRS - Inspection 0000* BE CAREFUL WITH THE TEMPORARY PORCH POSTS |
11/09/2000 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection 0000* |
11/14/2000 | STUCCO MESH | DWITT | Approved | IVRS - Inspection 0000* APPROVED FOR ONE COAT AS NOTED STALE BOTH SIDES OF INSIDE CORNERS ON PORCHES NOT ONE STAPLE FOR BOTH SIDES CAULK REFRIGERANT LINES, CONDENSATE ETC FINISH THE TWO WINDOWS ON NORTHWALLS, EAST UNIT BE CAREFUL DRAGGING HOSES AROUND THE TEMPORARY PORCH POSTS |
11/15/2000 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* LOOKS GOOD |
11/17/2000 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* IF CORRECTIONS HAVE BEEN MADE IN COMMON WALL OK TO COVER DO NOT COVER KITCHEN WALLS UNTIL CORRECTIONS HAVE BEEN MADE AND INSPECTED PLEASE HAVE INSPECTION REPORTS ON SITE FOR VERIFICATION OF CORRECTIONS PLEASE HAVE "AS BUILT" GAS ISOMETRIC AND SIZING AVAILABLE AS PRINT DOES NOT REFLECT INSTALLATION |
11/17/2000 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection 0000* OK TO CLEAR CABLE DROPS FOR #2  NOTE: 2- ROMEX CONDUTORS IN THE AREA OF THE ACCESS PANEL IN WASH ROOM (EAST) NEED TO BE MOVED, THEY NEED TO BE OUT OF THE WAY FOR PEOPLE CLIMBING IN AND REMOVING COVER WILL CHECK ON FINAL |
11/21/2000 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000* |
12/01/2000 | SHEET ROCK NAILING | AQUIROZ | Approved | EXCLUDES 1 HOUR WALL BETWEEN APPOINTMENT. |
03/29/2001 | BUILDING - FINAL | DWITT | Approved | IVRS - Inspection 0000* |
03/29/2001 | U VALUE FOR WINDOW | DWITT | Approved | |
04/10/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* |