Permit: T99CM02370
Permit Details
Apply Date:
05/18/1999
Applicant:
DIAMOND KEY HOMES INC
Description:
SFR:TD#13-60-67
Contractors:
- DIAMOND KEY HOMES INC
Completed Inspections
Permit Status: Final
Permit Number: T99CM02370
Permit Description: SFR:TD#13-60-67
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/1999 | ROOF NAILING | MSNYDER | Approved | ADDTL COMMS - 1. NEEDING ENGINEERING ON SHEAR LOOSE ON BACK WALL. 2. 3 PNT BEARING TRUSSES CALLED FOR AT PATIO. 3. NON BEARING WALLS NEEDS 1/2 CLEARANCE TO TRUSSES PROVIDE BEFORE LOADING ROOF. 4. NAILING MISSING AT SHEAR TRANSFER. 5. VERIFY REPLACEMENT OF 4X12 BEAM AT PORCH WITH 3 1/8 X 10 3/8 GLUE LAMB CHECK AT FINAL FRAMING. |
| 07/20/1999 | PLUMBING - INTERMEDIATE | MSNYDER | Approved | PARTIAL APPROVAL |
| 07/20/1999 | ELECTRIC - INTERMEDIATE | MSNYDER | Approved | PARTIAL APPROVAL |
| 07/21/1999 | FRAMING | MSNYDER | Approved | PARTIAL APPROVAL |
| 07/21/1999 | FRAMING | MSNYDER | Approved | ADDTL COMMS - ENGINEERING STILL REQUIRED DRYWALL AT OWN RISK. ALL OTHER INTERMEDIATE OKAY |