| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/1999 | ROOF NAILING | RFREIDIN | Approved | ADDTL COMMS - 2. TRUSS C-1 NEED FLAT BRACE AT TOP CHORD BETWEEN JOINT 3-4 |
| 05/03/1999 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | ADDTL COMMS - 1. MISSED H.D EAST WALL. |
| 06/09/1999 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | ADDTL COMMS - 1. OUTLET OPPOSITE SINK (KITCHEN) IF COUNTER TOO BE INSTALLED AND OVER HANGS MORE THAN 6 CANNOT BE THERE REMOVE, IF COUNTER LESS THAN 6 OVER HANG MOVE OUTLET UP TO WITHIN 1 0 OF FLAT TOP SURFACE. |
| 06/09/1999 | FRAMING | RFREIDIN | Approved | ADDTL COMMS - 3. WHATS IN LSL BEAM NO STAMP ON BEAM? DONT LOAD ROOF UNTIL VERIFIED. 4. WHO MAKES THE GULT 3-5 HANGER? |