Last Inspection Date Description Inspector Results Comments
07/19/1999 BUILDING - FINAL N/A Correction Required ADDTL COMMS - 1. CAULK EXTERIOR PENETRATION. 5. CONCRETE NOT STAMP POST TEN. 9. FIRE CAULK FIRE PLACE. 10. SELF CLOSIGN DOOR DOES NOT CLOSE (GARAGE 10. SELF CLOSIGN DOOR DOES NOT CLOSE (GARAGE). 17. SAFETY GLASS AT FRONT DOOR.
07/19/1999 ELECTRIC - FINAL N/A Correction Required ADDTL COMMS - 3. EXTERIOR MISSING FIXTURES. 7. PLUG HOLE IN BOTTOM OF PANEL. ELECTRIC. 14. ANCH FLEX ELECTRIC AT ISLAND. 15. NO POWER TO LIGHTING UNDER CABINETS. 16. ANCHOR FLEX ELECTRIC UNDER COOK TOP.
07/19/1999 PLUMBING - FINAL N/A Correction Required ADDTL COMMS - 6. NO POST TENSION TAG ON WATER. 11. DRAFT HOOD ON HOT WATER NOT CONNECTED. 12. COVER PLUMBING UNDER SINK. 13. NO CORD ON DISPOSAL.
07/19/1999 MECHANICAL - FINAL N/A Correction Required ADDTL COMMS - 4. RAISE FLUE 1-0 ABOVE PARAPET. 8. REMOVE DAMPER FROM FIRE PLACE.

Completed Inspections

Permit Status: Expired
Permit Number: T99CM01102
Permit Description: SFR
Total Completed Inspections - 2
Date Description Inspector Results Comments
06/08/1999 PLUMBING - GAS PRESSURE TEST RAIELLO Approved ADDTL COMMS - 11 PSI AIR TEST
06/08/1999 U VALUE FOR WINDOW RAIELLO Approved ADDTL COMMS - .81/.81