Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
11/12/1998
Applicant:
U S HOMES OF ARIZONA
Description:
SFR:13-82-86
Contractors:
  • U S HOMES OF ARIZONA

Completed Inspections

Permit Status: Final
Permit Number: T98CM04975
Permit Description: SFR:13-82-86
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/29/1998 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection 0999*
12/29/1998 FRAMING JRIVA Approved IVRS - Inspection 0160*
12/29/1998 FRAMING JRIVA Approved ADDTL COMMS - 1. PROVIDE PROOF THAT HOLD DOWNS HAVE HILT. QUILK BOLT TWO ANCHORS. 2. PROVIDE DATA ON METAL PRODUCTS USED IN LIEU OF SIMPSON. 3. DRYER DUCT MUST EXHAUST OUTSIDE. 4. NO LOT ID OR ADDRESS. 5. TRUSS TC CLIPS IMPROPERLY NAILED PREVENTING TRUSS MOVMENT. 6. RED HEADS LOOSE. 7. PROVIDE TRUSS DRAWINGS TO VARIFY LOAD AT 6 CUT TRUSSES. (DEADWOOD?). 8. WINDOWS NOT INSTALLED. 9. PROVIDE #1 SHEAR BEHIND TUB PER PLAN.

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW