Permit: T98CM03134
Permit Details
Apply Date:
07/21/1998
Applicant:
SIERRA LAND SURVEYING
Description:
APARTMENT BUILDING #7
Contractors:
- SIERRA LAND SURVEYING AND DEVELO
Completed Inspections
Permit Status: C of o
Permit Number: T98CM03134
Permit Description: APARTMENT BUILDING #7
Total Completed Inspections - 29
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/06/2000 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | ADDTL COMMS - 1. SOIL WATER TEST OK 2. HCS CONNECTION OK 3. OK TO BACKFILL |
10/06/2000 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
03/13/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
08/02/2001 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
11/14/2001 | STUCCO MESH | AMATHIES | Approved | |
01/03/2002 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
01/03/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
01/03/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
01/07/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
01/09/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR SHEETROCK ALL CORRECTIONS HAVE BEEN MADE. |
01/09/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) OK FOR DRYWALL. |
01/29/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
04/02/2002 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection 0000* OK FOR TEMP POWER. |
04/02/2002 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection 0000* |
04/02/2002 | BUILDING - TEMP POWER FOR TEST | AQUIROZ | Approved | |
04/02/2002 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection 0000* |
04/04/2002 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | |
04/04/2002 | PLUMBING - TEMP POWER FOR TEST | TRINIVJR | Approved | |
04/04/2002 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | |
04/10/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
04/10/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
04/11/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
04/11/2002 | FIRE - FINAL | SRYAN | Approved | |
04/11/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK C OF O. |
04/11/2002 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection 0000* |
04/11/2002 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000* |
04/12/2002 | PERMIT FINALED | AQUIROZ | Approved | |
04/12/2002 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
04/15/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved |