Permit: T98CM01004
Permit Details
Apply Date:
03/09/1998
Applicant:
CRADDOCK EDWARD C & AMY T JT/RS
Description:
ADDITION:UTILITY ROOM & REMODEL:PORCH TO LR & BATH
Completed Inspections
Permit Status: Final
Permit Number: T98CM01004
Permit Description: ADDITION:UTILITY ROOM & REMODEL:PORCH TO LR & BATH
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/1998 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | ADDTL COMMS - 1. SEE DETAIL BELOW ALL FOOTINGS TO BE 12 BELOW NATURAL GRADE. 2. WRAP PLUMBING TO BE INCONTACT WITH CONCRETE. 3. INSTALL BLOCK OUT OR INSTALL THE TWO P-STRAPS 1 TUB 1 SHOWER. |
| 05/06/1998 | ROOF NAILING | RFREIDIN | Approved | ADDTL COMMS - 1. PLAN HAS 2X10 RAFTERS YOU HAVE 2X8S PROBABLY OK HAVE SOMEONE IN YOUR OFFICE CALC. THEM JUST TO BE SURE. 2. METAL PLATE ALL A.B.S PIPE AT BOTTOM PLATE. 3. 2 LAYERS OF GRADE D PAPER OVER PLYWOOD SUB STRATE IF FOAM NOT USED. |