Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T98CM00483
Permit Details
Apply Date:
02/05/1998
Applicant:
SONORA EXPEDITING
Description:
TI:OFFICE
Architects:
- DENNEHY, ANDREW BALLING
Contractors:
- SHULL JONES BUILDERS ,
Completed Inspections
Permit Status: Final
Permit Number: T98CM00483
Permit Description: TI:OFFICE
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/1998 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | ADDTL COMMS - PROVIDE 3- 5/8 BOLTS PER 4/A-1 AT EACH LINTEL. |
03/27/1998 | FRAMING | EMONAHAN | Approved | ADDTL COMMS - NEED BLOCKING FOR HANDICAP GAB BARS IN TOILET. |
04/02/1998 | SHEET ROCK NAILING | DWITT | Approved | ADDTL COMMS - 1. RE-SCREW WHERE PAPER IS BROKEN. 2. RE-SCREW WHERE SCREWS ARE LESS THAN 3/8 FROM EDGE. 3. PROVIDE BACKING AND SCREW WHERE BACKING WAS MISSED OR WHERE SHEET WAS CUT WRONG. 4. FINISH SCREWING. 1 MARKED SOME OF THEM. |
04/27/1998 | ELECTRIC - FINAL | JORTA | Approved | DENIED |