Completed Inspections
Permit Status: Final
Permit Number: T98CM00065
Permit Description: SFR:TD#13-77-01
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/21/1998 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | ADDTL COMMS - HAVE AS BUILT FOR SEWER LINE PUT ON SITE PLAN & SUBMIT |
| 02/18/1998 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | ADDTL COMMS - 1. TRUSS TO GIRDER HANGER NEED HANGER TO BE PUT ON PLANS OR REACTION WAD ON TRUSS SHOP DRAWING LOAD IN LBS. AT THAT POINT TRUSS DRAWINGS NEEDED AT NEXT INSP. 2. K.C. HANGER USED IF APPROVED FOR THIS HOUSE A 10DS REQD 8D INSTALLED WILL CHECK AT NEXT INSP. |
| 02/27/1998 | FRAMING | RFREIDIN | Approved | ADDTL COMMS - 1. HANGER AT GIRDER TRUSSES OK PER PLAN BUT! PER K.C MANUAL HANGER S-26 WILL MAX 850 LBS REACTION LOAD FROM TRUSS DRAWING AT GIRDER TO GIRDER TRUSS IS 931 LBS. |