Permit: T98CM00063
Permit Details
Apply Date:
01/07/1998
Applicant:
JIMENEZ DAVID C & RAMONA M JT/RS
Description:
ADDITION:KITCHEN
Completed Inspections
Permit Status: Final
Permit Number: T98CM00063
Permit Description: ADDITION:KITCHEN
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/01/1998 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | ADDTL COMMS - 1. UNCOVER SOIL PIPE. 2. NEED TO VENT THE SHOWER TRAP ARM. 3. LOWER KITCHEN HORIZONTAL INSTALL 90 DEGREE FITTINGS AND GO VERTICAL. |
04/03/1998 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | ADDTL COMMS - 1. PLUMB SOIL LINES AS EXPLAINED. 2. WRAP ALL LINES IN CONTACT WITH CONCRETE. 3. MINIMUM 1/4 PER FT FOR SOIL LINE PITCH. 4. UNCOVER 3 LINE AND LOWER TO SEWER. |
04/28/1998 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | ADDTL COMMS - 1. NEED GAS TEST. 2. UNION TOO BE 6 ABOVE GRADE. 3. USE BRASS OR COPPER AT HOSE BIB DISSIMILAR METAL WILL CAUSE CORROSION. 4. NEED C.O AT KITCHEN VERTICAL DRAIN. 5. FAN REQUIRED IN OLD BATH ROOM. |