Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
RESIDENTIAL WALL
Address:
3945 E HOLMES ST
Address NEW:
3945 E HOLMES ST
Apply Date:
12/10/1998
Applicant:
PIONEER POOLS
Description:
WALL:PATIO 120LF OF 6HIGH
Contractors:
  • PIONEER POOLS

Outstanding Inspections

Permit Status: Expired
Permit Number: T98BU03017
Permite Description: WALL:PATIO 120LF OF 6HIGH
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
STEM WALL/RETAINING WALL N/A Not Inspected
PERMIT FINALED N/A Not Inspected
01/27/1999 BUILDING - FINAL N/A Correction Required ADDTL COMMS - NEED VERIFICATION OF 1005 INSPECTION & APPROVAL
12/15/1998 EXCAVATION/LAYOUT REBAR & ZON N/A Correction Required ADDTL COMMS - HORIZONTAL REBAR MUST BE 3 ABOVE BOTTOM OF FTG, YOUR HORIZONTAL REBAR IS AT PLACES SO HIGH AS TO BE IN NEUTRAL ZONE OF FTG WRAP AND SLEEVE ALL PIPES RUNNING ACROSS FTGS.

Completed Inspections

Permit Status: Expired
Permit Number: T98BU03017
Permit Description: WALL:PATIO 120LF OF 6HIGH
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/23/1998 REINFORCED MASONRY PRE-GROUT ROTERO Approved ADDTL COMMS - NOTE:PERMIT NOT ON SITE WILL SIGN 2ND LIFT