Permit: T98BU03015
Permit Details
Apply Date:
12/10/1998
Applicant:
ARTISTIC POOL AND SPAS INC
Description:
POOL & SPA:GUNITE TD#13-43-52
Contractors:
- ARTISTIC POOL AND SPAS INC
Completed Inspections
Permit Status: Final
Permit Number: T98BU03015
Permit Description: POOL & SPA:GUNITE TD#13-43-52
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/1998 | POOL/SPA PRE-GUNITE | RAIELLO | Approved | DENIED |
| 12/29/1998 | POOL/SPA PRE-GUNITE | RAIELLO | Approved | ADDTL COMMS - 1. YOU NEED TO LOOK AT 8-6 BOWL STEEL, TO BE 6 O.C. PER PLAN. 2. THERE IS NO GROUNDING BOND FOR WROUGHT IRON ENCLOSURE. 3. PLAN CALLS FOR CUPS, IF THIS IS FOR HAND RAILS THEY WILL NEED TO BE BONDED. 4. AT PRE-GUNITE WE SHOULD ALSO BE INSPECTING PLUMBING TEST, GAS (IF USED), ELECTRICAL. YOUR PERMIT CARD DOES NOT INDICATE THESE INSPECTIONS? |