Permit: T98BU02938
Permit Details
Apply Date:
12/01/1998
Applicant:
QUIHUIS CHRISTOPHER DANIEL
Description:
POOL:ABOVE GROUND T98VL00624
Outstanding Inspections
Permit Status: Expired
Permit Number: T98BU02938
Permite Description: POOL:ABOVE GROUND T98VL00624
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PERMIT FINALED | N/A | Not Inspected | ||
| 04/13/1999 | POOL/SPA ELECTRIC | N/A | Correction Required | ADDTL COMMS - 4. DELETE LIGHT OR WIRE PROPERLY BY A LICENSED POOL ELECTRICIAN. 5. RECEPT NEEDED BETWEEN 10 TO 20 FROM POOLS EDGE AND GFCI PROTECTED. 7. GFCI PROTECTION NEEDED FOR ELEC FOR LIGHT. 8. #8 COPPER NEEDED TO BOND POOL MOTOR, BARRIER AND ACCESSORIES. |
| 04/13/1999 | POOL/SPA FINAL/BARRIER | N/A | Correction Required | ADDTL COMMS - 1. BARRIER NEEDS TO BE SECURED AND GATE TO LATCH. 2. BONDING WAS NOT INSPECTED. 3. NEED FENCE AND PUMP MOTOR BONDED. 6. POOL FILLED WITH WATER AT THIS TIME. |