Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Apply Date:
05/08/1997
Applicant:
BACH HOWARD A & PATRICIA L TR
Description:
ADDITION:GARAGE & WORKSHOP

Completed Inspections

Permit Status: Final
Permit Number: T97CM01196
Permit Description: ADDITION:GARAGE & WORKSHOP
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/29/1998 ELECTRIC - INTERMEDIATE RFREIDIN Approved NOT READY FOR INSPECTION
12/29/1998 ELECTRIC - INTERMEDIATE RFREIDIN Approved ADDTL COMMS - 1. CALL FOR ELECT INTERMEDIATE WHEN THE ROOF IS ON. YOU NEED TO RUN ALL ROMEX MAKE UP BOXES. IF METAL, REQUIRE BOND JUMPER. B) COUNTER TO BE ON 20 AMP CIRCUIT. C) LIGHTING CIRCUITS. D) CHECK WATTAGE DEMANDS OF ALL EQUIPMENT BEFORE RUNNING WIRE. E) GARAGE REQUIRES GFCI OUTLET MINIMUM (1) IF MORE THAN ONE ALL OUTLETS TO BE GFCI PROTECTED. F) YOU NEED AN INSPECTION ON FEEDER FROM SERV. TO NEW PANEL BOARD INSTALLED. ISOLATEE NEUTRALS AND GROUNDS AT NEW PANEL. IF 4 WIRE FEEDER RUN GRD/ROD NOT REQUIRED AT NEW PANEL. G) GOOD ADVICE WOULD BE TO INSTALL ALL OUTLETS BEFORE COVERING WITH SHEET ROCK TO VERIFY EVERYTHING WORKS. 3. ALL BOTTOM PLATES FOR FRAMING ARE TO BE TREATED LUMBER. YOU NEED TO COAT WITH COPPER CHROMATE OR EQUAL.
05/03/1999 FRAMING RFREIDIN Approved IVRS - Inspection 0000*
05/03/1999 FRAMING RFREIDIN Approved ADDTL COMMS - ROOF RAFTERS IN PLACE

Documents

File Name Document Type  
None DOCUMENTS VIEW