Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
1448 S AVENIDA SIRIO
Apply Date:
03/10/1997
Applicant:
NOPERI CLAUDIO & REGINA JT/RS
Description:
ADDITION AND REMODEL EXST RESIDENCE

Outstanding Inspections

Permit Status: Expired
Permit Number: T97CM00184
Permite Description: ADDITION AND REMODEL EXST RESIDENCE
Total Outstanding Inspections - 16
Last Inspection Date Description Inspector Results Comments
SHEET ROCK NAILING N/A Not Inspected
ELECTRIC - UFER N/A Not Inspected
ELECTRIC - CABLE DROP N/A Not Inspected
ELECTRIC - TEMPORARY SERVICE N/A Not Inspected
PLUMBING - ROUGH, SOIL N/A Not Inspected
PLUMBING - INTERMEDIATE N/A Not Inspected
PLUMBING - YARD WTR LINE/TEST N/A Not Inspected
PLUMBING - SEWER HCS CONNECT N/A Not Inspected
MECHANICAL - INTERMEDIATE N/A Not Inspected
PERMIT FINALED N/A Not Inspected
02/02/1999 BUILDING - FINAL N/A Correction Required ADDTL COMMS - 1. RAISE H2O HEATER FLUE 1 ABOVE COOLER. 2. FIREPLACE IS GOING TO BE A LOG LITER, OR GAS LOG PLEASE INSTALL. 3. FINISH KITCHEN, CABINETS AND PLUMBING, RANGE PAN. 4. BATHROOM PLUMBING LIGHTING FIXTURES NOT COMPLETE. 5. EXT OUTLETS NOT INSTALLED. 6. NEED A STOOP AT REAR DOOR 3X3 CAN BE BRICK 4 STEP. 7. ELECT SERVICE HAS NOT BEEN CONNECTED BY T.E.P WAS IT INSPECTED? H2O BOND? 8. COOLER OUTLET TRAPPED UP UNABLE TO INSPECT. 9. NEED CONDENSATE LINE FOR A.C. 10. SUPPORT/SECURE GAS LINE.
02/02/1999 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0999*
02/02/1999 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*
02/02/1999 MECHANICAL - FINAL N/A Denied IVRS - Inspection 0999*
07/12/1999 ELECTRIC - SERVICE UPGRADE N/A Correction Required ADDTL COMMS - YOU NEED TO EXPOSE GROUNDING AND H20 BOND. 2 GRD RODS REQUIRED PLUS WATER BOND.
11/20/1997 ELECTRIC - INTERMEDIATE N/A Correction Required ADDTL COMMS - 1. PLEASE LABEL CIRCUITS IN PANEL 60 TWO POLE BREAKER NOT ON PANEL SCHEDULE OR LOAD CALC 2. DRYER VENT STRAP OUTSIDE REMOVE SCREW FROM INSIDE OF VENT.

Completed Inspections

Permit Status: Expired
Permit Number: T97CM00184
Permit Description: ADDITION AND REMODEL EXST RESIDENCE
Total Completed Inspections - 4
Date Description Inspector Results Comments
07/08/1997 ROOF NAILING HLEYVA Approved ADDTL COMMS - NOTE - YOU ARE REPLACING BEDROOM WINDOWS THAT DO NOT MEET MINIMUM REQUIREMENTS FOR OPENING & LIGHT
11/20/1997 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved NOT READY FOR INSPECTION
11/20/1997 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved ADDTL COMMS - 1. GAS LINE NOT ALLOWED UNDER ROOF STRUCTURE AT REAR DOOR. 2. FURANCE NOTHING ON PLAN SHOWING ANY CHANGES OLD FURANCE ROOM HAS NO PLENUM, VERIFY RELIEF/COMB DUCTS TO OUTSIDE VENTING. 3. 2 PIPE IN KITCHEN FLOOR? 4. MISSING FIRE PLACE HEARTH SAFTEY STRIP. 5.DUCT WORK TO BE INSULATED 1 MIN VAPOR BARRIER FOR HEATING DUCT. 6. BLOCK ALL MECH. VENTS 3 SIDES.
08/27/1998 STUCCO MESH RFREIDIN Approved ADDTL COMMS - YOU NEED A PLASTER GROUND AT FREEZE BOARDS COVERED PORCH REAR TOP OF WALL