Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Floodplain Use
Address:
309 N PARK AV
Apply Date:
04/26/2022
Applicant:
James McMahon
Description:
Floodplain Use Permit for converting SFR to Duplex with Additions

Permit Reviews

Permit Number - T22OT00306
Permit Status: Issued
Permit Description: Floodplain Use Permit for converting SFR to Duplex with Additions
Start Date Submittal Complete Date Status  
10/10/2022 PLANS OK TO SUBMIT - FLOODPLAIN 10/10/2022 COMPLETED Review Details

Conditions

Permit Number - T22OT00306
Permit Status: Issued
Permit Description: Floodplain Use Permit for converting SFR to Duplex with Additions
Date Description Comments
10/10/2022 Floodplain Use Permit T22OT00306October 10, 2022, Elevation Certificate Required  The applicant is authorized to use a portion of the Special Flood Hazard Area (Panel 2277L High School Wash FP) in the City of Tucson at 309 N Park Av for Residential Demo, remodel, and attached duplex constructionThe applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and is particularly bound by the conditions stated below.  Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit.  Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require the issuance of an additional Floodplain Use Permit.   The following conditions shall apply to this permit:   1. This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the building or site improvements, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from new building and site improvements within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.   2. All work shall conform to the attached plans (T22CM01013) which are made part of this permit.  3. The construction cost of the improvements on the existing structure (including the demolition and remodeling) shall not exceed 50 per cent of the total appraised/assessed value of the existing structure, not including the land.The estimated cost of the afermentioned improvements are $65,000.00 based on contractor estimate.The estimated value of the existing structure is $165,685.00 based on A recent sale listed on the Pima County Assessor websiteThe cost of the improvements is 39.23 percent of the value of the existing structure. The total cost of all improvements to the structure in any 10-year period must not exceed 50 per cent of the value of the structure."4. The lowest floor of the new structure and any utilites (HVAC, etc) shall be elevated to the regulatory flood elevation and certified by a registered land surveyor. The base flood elevation is 2402.6 FT NAVD 1988. The regulatory flood elevation is 2403.6 FT NAVD 1988.5. The elevation certificate will be submitted to the engineering section of PDSD and approved before the pre-slab inspection is scheduled and again before the final inspection is scheduled."6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard, or divert the existing flow of floodwaters from or to adjacent properties.   7. Any additional future disturbance of the floodplain including the construction of any fences, walls or accessory structures shall have separate floodplain use permit applications submitted to this office for review and approval.   This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with.