Permit: T22CM07809
Permit Details
Apply Date:
10/12/2022
Applicant:
Dana Petty
Description:
SFR MER1301600 T21-M0073
Outstanding Activity Conditions
Permit Number - T22CM07809
Permit Status: Issued
Permit Description: SFR MER1301600 T21-M0073
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
10/12/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
10/12/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
10/12/2022 | NO FINAL UNTIL THE PUBLIC SEWER G-2020-095/P22WP00021 IS ACCEPTED AND RELEASED BY PCRWRD |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM07809
Permite Description: SFR MER1301600 T21-M0073
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/03/2023 | COT - RSPL - Rough Soil | N/A | Canceled | Inspection completed yesterday. |
10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM07809
Permit Description: SFR MER1301600 T21-M0073
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/27/2023 | COT - RSPL - Yard Water Line | Passed | ||
01/10/2023 | COT - RSEL - Grounding/Bonding | Passed | ||
01/10/2023 | COT - RSBU - Preslab | Passed | ||
01/10/2023 | COT - RSEL - Electrical Underground | Passed | ||
01/27/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
01/27/2023 | COT - RSBU - Roof Nailing | Passed | ||
03/01/2023 | RSME - Mechanical Progress | Passed | ||
03/01/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
03/01/2023 | COT - LCPL - Plumbing Intermediate | Passed | ||
03/01/2023 | COT - RSEL - Construction Power | Passed | ||
03/01/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
03/01/2023 | COT - LCBU - Framing | Passed | ||
03/01/2023 | COT - RSPL - Gas Pressure Test | Passed | ||
03/17/2023 | COT - HCBU - Interior Shear Bracing | Passed | ||
03/30/2023 | COT - RSPL - Sewer | Passed | ||
05/22/2023 | COT - BULD - SWG Clearance | Passed | 5/22/23: SWG clearance issued. | |
05/22/2023 | COT - RSPL - Plumbing Final | Passed | ||
06/14/2023 | ENGR Engineering Final | Passed | ||
06/14/2023 | COT - RSEL - Electrical Final | Passed | AFCI & GFCI breakers are installed in electrical panel, panel is properly labeled. Electrical outlets and fixtures are installed and operational. Smoke detectors are functioning properly. | |
06/14/2023 | COT - RSEL - Outdoor Lighting | Passed | Outdoor lighting fixtures are installed and operational with the correct size light bulb for wattage. | |
06/14/2023 | COT - RSME - Mechanical Final | Passed | Mechanical equipment is installed and operational. A/C registers are installed. Thermostat is installed and operational. | |
06/14/2023 | RSBU - Building Final | Passed | Construction is complete on this house. Plumbing, electrical, and mechanical are all working well. Okay to issue a Certificate of Occupancy. |