Permit: T22CM07084
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
521 N TANQUE VERDE LOOP RD
Address NEW:
521 N TANQUE VERDE LOOP RD
Apply Date:
09/15/2022
Applicant:
Description:
Attached ADU
Permit Reviews
Permit Number - T22CM07084
Permit Status: Issued
Permit Description: Attached ADU
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/15/2022 | 3RD PARTY REVIEW - RESIDENTIAL | 10/20/2022 | COMPLETED |
| 12/22/2022 | RESIDENTIAL NEW DWELLING v.1 | 12/23/2022 | APPROVED |
Conditions
Permit Number - T22CM07084
Permit Status: Issued
Permit Description: Attached ADU
| Date | Description | Comments |
|---|---|---|
| 10/19/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
| 12/23/2022 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM07084
Permite Description: Attached ADU
Total Outstanding Inspections - 12
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/06/2023 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 3-24-23: Footings for porch are not 12” below undisturbed ground surface per R403.1.4. |
| 03/24/2023 | COT - RSBU - Roof Nailing | N/A | Partial Pass | 3-24-23: Addition roof only; porches remain. |
| 05/23/2023 | RSEL - Electrical Progress | N/A | Re-inspection required | 5/23/23: I joist hangers missing nailing (All), plumbing not under test, receptacles in bathroom not wired |
| 12/28/2023 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 12/28/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Applicable | 12/28/23: duplicate inspection |
| 12/28/2023 | COT - RSBU - Interior Shear Bracing | N/A | Not Applicable | 12/28/23: duplicate inspection |
| 12/28/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Applicable | 12/28/23: duplicate inspection |
| 12/28/2023 | COT - RSEL - Electrical Underground | N/A | Not Applicable | 12/28/23: duplicate inspection |
| 12/28/2023 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 12/28/2023 | COT - RSPL - Rough Soil | N/A | Not Applicable | 12/28/23: duplicate inspection |
| 12/28/2023 | COT - RSPL - Sewer | N/A | Not Applicable | 12/28/23: duplicate inspection |
| 12/28/2023 | COT - RSPL - Yard Water Line | N/A | Not Applicable |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM07084
Permit Description: Attached ADU
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2023 | COT - RSBU - Preslab | Passed | ||
| 02/16/2023 | COT - RSBU - Stem Wall/Retaining Wall | Passed | ||
| 05/03/2023 | COT - RSBU - Roof Nailing | Passed | ||
| 12/28/2023 | COT - RSME - Mechanical Final | Passed | ||
| 01/03/2024 | COT - RSEL - Electrical Final | Passed | ||
| 01/03/2024 | COT - RSPL - Plumbing Final | Passed |