Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
08/17/2022
Applicant:
Richard Willard
Description:
SFR LE23006 T22-M0054

Permit Reviews

Permit Number - T22CM06312
Permit Status: Issued
Permit Description: SFR LE23006 T22-M0054
Start Date Submittal Complete Date Status  
08/17/2022 OTHER 08/22/2022 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T22CM06312
Permit Status: Issued
Permit Description: SFR LE23006 T22-M0054
Total Outstanding Activity Conditions - 6
Date Name
07/11/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/11/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/17/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
08/17/2022 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
08/17/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/17/2022 NO FINAL UNTIL THE PUBLIC SEWER G-2020-098/P22WP00026, THE PUBLIC OFFSITE SEWER G-2020-058/P21WP00065 FOR PARCEL 3, THE PUBLICOFFSITE SEWER G-20-20-101/P21WP00064 FOR PARCEL 4, AND THE PUBLIC SEWER G-2020-090/P21WP00062 FOR PARCEL 5, IS ACCEPTED AND RELEASED BY PCRWRD

Outstanding Inspections

Permit Status: Issued
Permit Number: T22CM06312
Permite Description: SFR LE23006 T22-M0054
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - RSPL - Sewer N/A Not Ready
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: T22CM06312
Permit Description: SFR LE23006 T22-M0054
Total Completed Inspections - 23
Date Description Inspector Results Comments
09/21/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 09/21/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Approved. Shading required.}
09/21/2022 COT - RSPL - Yard Water Line Passed {Activity date: 09/21/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Approved}
10/13/2022 COT - RSEL - Electrical Underground Passed {Activity date: 10/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 10/12/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} ; {Activity date: 10/05/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready.}
10/14/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 10/14/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 10/13/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - AP canceled} ; {Activity date: 10/13/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE} ; {Activity date: 10/12/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} ; {Activity date: 10/05/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready. Missing UFER rebar. Stake UFER rebar.}
10/14/2022 COT - RSBU - Preslab Passed {Activity date: 10/14/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 10/12/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Not ready. Support tension cables off the ground.} ; {Activity date: 10/05/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready}
10/14/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 10/14/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 10/13/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE
1. Isolate ufer from all metal by min 2” and support ufer in trench
2.remove all construction debris from pad} ; {Activity date: 10/12/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Not ready. Missing rebar in the center of reentrant, corner of floor slab.} ; {Activity date: 10/11/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE
Maintain min 3" clearance of rebar and hold-downs to earth an all sides. Maintain min 2" clearance of rebar and hold downs to forms.
Cancel all other inspections} ; {Activity date: 10/05/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready. Missing hold down plates. Rebar in footing needs to be 3” away and above ground.
}
11/21/2022 COT - RSBU - Exterior Clips/Sheathing Passed
11/21/2022 COT - RSBU - Roof Nailing Passed
01/26/2023 COT - RSEL - Construction Power Passed TEP ECO
03/07/2023 COT - RSPL - Gas Pressure Test Passed Approved. Holding 15 psi.
03/07/2023 COT - RSPL - Rough Soil Passed Approved. Okay to backfill. Shading required.
03/07/2023 COT - LCBU - Framing Passed
03/09/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3/9/2023 approved. Corrections were made
03/09/2023 RSME - Mechanical Progress Passed 3/9/2023 approved. Corrections were made
03/20/2023 COT - HCBU - Interior Shear Bracing Passed
03/24/2023 COT - RSPL - Sewer Passed Pass
06/14/2023 COT - BULD - SWG Clearance Passed
06/16/2023 COT - RSPL - Plumbing Final Passed
06/16/2023 COT - RSME - Mechanical Final Passed
06/16/2023 RSBU - Building Final Passed 6/16/23: Missing "For Future solar use" label on deadfront of service, missing WR outlet outside at back porch, base for a/c unit needs 3" clearance from earth.
06/16/2023 COT - RSEL - Electrical Final Passed
06/16/2023 COT - RSEL - Outdoor Lighting Passed
06/16/2023 ENGR Engineering Final Passed

Documents

File Name Document Type  
APPLICATION.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
SIC.PDF DOCUMENTS VIEW
SITE PLAN.PDF DOCUMENTS VIEW