Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
08/09/2022
Applicant:
Andrea Flood
Description:
SFR F40G22 T22-M0025

Permit Reviews

Permit Number - T22CM06087
Permit Status: Issued
Permit Description: SFR F40G22 T22-M0025
Start Date Submittal Complete Date Status  
10/16/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 10/17/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T22CM06087
Permit Status: Issued
Permit Description: SFR F40G22 T22-M0025
Total Outstanding Activity Conditions - 1
Date Name
08/09/2022 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Conditions

Permit Number - T22CM06087
Permit Status: Issued
Permit Description: SFR F40G22 T22-M0025
Date Description Comments
08/09/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
08/09/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/11/2022 PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE PERMIT.
08/11/2022 Prior to permit issuance a General Contractor Letter (GCL) is required
10/17/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
10/17/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/17/2023 ISSUED WITH PCRWRD CONDITIONS: NO FINAL UNTIL THE PUBLIC SEWER G-2020-053/P20WP00249 IS ACCEPTED AND RELEASED PCRWRD
10/17/2023 Post-Tension Inspection Report is required.
10/17/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Outstanding Inspections

Permit Status: Issued
Permit Number: T22CM06087
Permite Description: SFR F40G22 T22-M0025
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
04/03/2023 COT - LCPL - Plumbing Intermediate N/A Re-inspection required Shim mid bearing point of truss, shower vent has reverse slope at floor, located smoke det per sealed plans.
04/03/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Shim mid bearing point of truss, shower vent has reverse slope at floor, located smoke det per sealed plans.

Completed Inspections

Permit Status: Issued
Permit Number: T22CM06087
Permit Description: SFR F40G22 T22-M0025
Total Completed Inspections - 24
Date Description Inspector Results Comments
09/14/2022 COT - RSPL - Yard Water Line Passed {Activity date: 09/14/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 09/12/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Valve was loose. Provide under pressure.
} ; {Activity date: 09/09/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Canceled per contractor.}
09/14/2022 COT - RSPL - Sewer Passed {Activity date: 09/14/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 09/12/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready} ; {Activity date: 09/09/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Canceled per contractor.}
09/14/2022 COT - RSPL - Rough Soil Passed {Activity date: 09/14/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 09/12/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Moisture near fitting.} ; {Activity date: 09/09/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Canceled per contractor.}
09/26/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 09/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
09/26/2022 COT - RSBU - Preslab Passed {Activity date: 09/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
09/26/2022 COT - RSEL - Electrical Underground Passed {Activity date: 09/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
09/26/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 09/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
11/21/2022 COT - RSBU - Roof Nailing Passed
11/21/2022 COT - RSBU - Exterior Clips/Sheathing Passed
04/03/2023 BULD - Electrical Clearance Passed TEP ECO
04/03/2023 RSME - Mechanical Progress Passed
04/03/2023 COT - RSEL - Construction Power Passed
04/03/2023 COT - RSPL - Gas Pressure Test Passed
04/03/2023 COT - LCBU - Framing Passed
04/06/2023 COT - LCPL - Plumbing Intermediate Passed 4/6/2023: all corrections made
04/06/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 4/6/2023: all corrections made
04/20/2023 COT - HCBU - Interior Shear Bracing Passed
07/14/2023 COT - RSPL - Plumbing Final Passed
07/14/2023 COT - BULD - SWG Clearance Passed
07/27/2023 COT - RSEL - Outdoor Lighting Passed
07/27/2023 COT - RSME - Mechanical Final Passed
07/27/2023 COT - RSEL - Electrical Final Passed
07/27/2023 RSBU - Building Final Passed
08/10/2023 ENGR Engineering Final Passed

Documents

File Name Document Type  
CONS-1_SPECIAL INSPECTION_PT FINAL_V1.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
SIC.PDF DOCUMENTS VIEW
SITE PLAN.PDF DOCUMENTS VIEW