Permit: T22CM05499
Permit Details
Apply Date:
07/20/2022
Applicant:
Sunrun Installation Services, Inc
Description:
R - - SYSTEM SIZE: 7665W DC, 6000W AC - MODULES: (21) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPH-365M - INVERTERS: (1) GROWATT NEW ENERGY TECHNOLOGY CO LTD: MIN 6000TL-XH-US - RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE WITH STANDOFF TO RAFTER: SNR-DC-01249 - RAPID SHUTDOWN: (21) TIGO ENERGY, INC TS4-A-F ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
Architects:
- Same as above
Contractors:
- Sunrun Installation Services, Inc
Permit Reviews
Permit Number - T22CM05499
Permit Status: Final
Permit Description: R - - SYSTEM SIZE: 7665W DC, 6000W AC
- MODULES: (21) LONGI GREEN ENERGY TECHNOLOGY CO
LTD: LR4-60HPH-365M
- INVERTERS: (1) GROWATT NEW ENERGY TECHNOLOGY CO
LTD: MIN 6000TL-XH-US
- RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE
WITH STANDOFF TO RAFTER: SNR-DC-01249
- RAPID SHUTDOWN: (21) TIGO ENERGY, INC TS4-A-F
ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/20/2022 | OTHER | 07/25/2022 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T22CM05499
Permit Description: R - - SYSTEM SIZE: 7665W DC, 6000W AC
- MODULES: (21) LONGI GREEN ENERGY TECHNOLOGY CO
LTD: LR4-60HPH-365M
- INVERTERS: (1) GROWATT NEW ENERGY TECHNOLOGY CO
LTD: MIN 6000TL-XH-US
- RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE
WITH STANDOFF TO RAFTER: SNR-DC-01249
- RAPID SHUTDOWN: (21) TIGO ENERGY, INC TS4-A-F
ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/23/2022 | TEP CLEARANCE - PM | TGAUSP | Approved | CODE DGC |
| 08/23/2022 | ELECTRIC - FINAL | TGAUSP | Approved | Approved, please send DGC Clearance to TEP for the solar meter |
| 08/23/2022 | BUILDING - FINAL | TGAUSP | Approved | Approved |