Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM05107
Permit Details
Apply Date:
07/07/2022
Applicant:
David Valencia
Description:
New Multi-Family BLDG #2
Permit Reviews
Permit Number - T22CM05107
Permit Status: Issued
Permit Description: New Multi-Family BLDG #2
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/07/2022 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 08/18/2022 | COMPLETED |
03/06/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/11/2024 | APPROVED |
11/10/2022 | COMMERCIAL REVIEW - FULL v.1 | 12/28/2022 | REQUIRES RESUBMIT |
05/02/2023 | COMMERCIAL REVIEW - FULL v.1 | 05/10/2023 | APPROVED |
02/17/2023 | COMMERCIAL REVIEW - FULL v.2 | 03/22/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM05107
Permit Status: Issued
Permit Description: New Multi-Family BLDG #2
Total Outstanding Activity Conditions - 14
Date | Name |
---|---|
02/27/2023 | AIR BALANCING/COMMISSIONING REPORT IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
02/27/2023 | Post-Tension Inspection Report is required. |
02/27/2023 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
02/27/2023 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
02/27/2023 | WATER STERILIZATION REPORT IS REQUIRED. |
03/08/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
12/12/2023 | |
12/12/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - T22CM05107
Permit Status: Issued
Permit Description: New Multi-Family BLDG #2
Date | Description | Comments |
---|---|---|
12/28/2022 | PLEASE CONTACT PC ADDRESSING TO HAVE BUILDING NUMBER ASSIGNED PRIOR TO ISSUANCE Ph# 520-724-9512, EMAIL:ADDRESSING@PIMA.GOV} | |
01/06/2023 | Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection. | |
02/27/2023 | I-Joists Designs must be submitted and approved prior to Final Inspection. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM05107
Permite Description: New Multi-Family BLDG #2
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/17/2024 | BULD - Electrical Clearance | N/A | Partial Pass | UG only. |
11/05/2024 | COT - HCBU - Building Final | N/A | Re-inspection required |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM05107
Permit Description: New Multi-Family BLDG #2
Total Completed Inspections - 27