Status:
Final
Type:
SOLAR WAIVER - RES
Apply Date:
05/31/2022
Applicant:
Sunrun Installation Services, Inc
Description:
R - SYSTEM SIZE: 3740W DC, 3840W AC - MODULES: (11) JA SOLAR: JAM60S10-340/MR - INVERTERS: (1) DELTA ELECTRONICS: E4-TL-US - RACKING: ; SOLLEGA FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE - MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW 225 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER. - RAPID SHUTDOWN: (11) APSMART RSD-S-PLC ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
Architects:
  • Same as above
Contractors:
  • Sunrun Installation Services, Inc

Permit Reviews

Permit Number - T22CM04086
Permit Status: Final
Permit Description: R - SYSTEM SIZE: 3740W DC, 3840W AC - MODULES: (11) JA SOLAR: JAM60S10-340/MR - INVERTERS: (1) DELTA ELECTRONICS: E4-TL-US - RACKING: ; SOLLEGA FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE - MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW 225 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER. - RAPID SHUTDOWN: (11) APSMART RSD-S-PLC ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
Start Date Submittal Complete Date Status  
05/31/2022 OTHER 07/15/2022 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T22CM04086
Permit Description: R - SYSTEM SIZE: 3740W DC, 3840W AC - MODULES: (11) JA SOLAR: JAM60S10-340/MR - INVERTERS: (1) DELTA ELECTRONICS: E4-TL-US - RACKING: ; SOLLEGA FASTRACK510 WITH 304 STAINLESS STEEL HARDWARE - MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW 225 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER. - RAPID SHUTDOWN: (11) APSMART RSD-S-PLC ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
Total Completed Inspections - 4
Date Description Inspector Results Comments
08/09/2022 ELECTRIC - SERVICE UPGRADE DQUINN Approved Ap
Called TEP at 12:45

Need solar for final

Clear incr
08/15/2022 TEP CLEARANCE - PM TGAUSP Approved CODE DGC
08/15/2022 ELECTRIC - FINAL TGAUSP Approved Approved, please send DGC Clearance to TEP for the solar meter
08/15/2022 BUILDING - FINAL TGAUSP Approved Approved