Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM03910
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
5317 E 26TH ST
Address NEW:
5317 E 26TH ST
Apply Date:
05/23/2022
Applicant:
Frank Rendon
Description:
SFR
Permit Reviews
Permit Number - T22CM03910
Permit Status: Inspections
Permit Description: SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/23/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 06/28/2022 | COMPLETED |
| 03/02/2023 | RESIDENTIAL NEW DWELLING v.1 | 05/18/2023 | REQUIRES RESUBMIT |
| 06/20/2023 | RESTAMP - RESIDENTIAL v.1 | 06/20/2023 | APPROVED |
| 06/15/2023 | RESIDENTIAL NEW DWELLING v.2 | 06/20/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM03910
Permit Status: Inspections
Permit Description: SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/08/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - T22CM03910
Permit Status: Inspections
Permit Description: SFR
| Date | Description | Comments |
|---|---|---|
| 07/27/2023 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 06/20/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: T22CM03910
Permite Description: SFR
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2023 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Ready | 11/29/23: not ready for this inspection |
Completed Inspections
Permit Status: Inspections
Permit Number: T22CM03910
Permit Description: SFR
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2023 | COT - RSPL - Rough Soil | Passed | ||
| 01/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 1/24/24: Footings are properly dug, rebar reinforcement is in place per plans, Ufer ground is properly installed to bottom rebar reinforcement of footing, and forms are in place for slab on grade. Okay to pour concrete. | |
| 01/24/2024 | COT - RSEL - Grounding/Bonding | Passed | 1/24/24: Footings are properly dug, rebar reinforcement is in place per plans, Ufer ground is properly installed to bottom rebar reinforcement of footing, and forms are in place for slab on grade. Okay to pour concrete. | |
| 08/28/2024 | COT - RSBU - Preslab | Passed | Okay to pour footings and slabs for back porch and carport | |
| 03/07/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Passed 3/7/25 ok to proceed to intermediate stage | |
| 03/07/2025 | COT - RSBU - Roof Nailing | Passed | Passed 3/7/25 ok to proceed to intermediate stage | |
| 06/26/2025 | BULD - Electrical Clearance | Passed | 6/26/25 TEP CLEARANCE: ECO |