Permit: T22CM03608
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
7660 S VIA CASA DE CAMPO
Address NEW:
7660 S VIA CASA DE CAMPO
Apply Date:
05/11/2022
Applicant:
Description:
SFR 130.1460 T21-M0026
Outstanding Activity Conditions
Permit Number - T22CM03608
Permit Status: Issued
Permit Description: SFR 130.1460 T21-M0026
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 05/11/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 05/11/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 05/11/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 05/11/2022 | NO FINAL UNTIL THE PUBLIC SEWER G-2020-100/P21WP00059, G-20-059/P20WP00060, G-20-089/P20WP00061 AND THE DOWNSTREAM OFFSITEPUBLIC SEWER FOR PARCEL 4 G-2020-087 IS ACCEPTED AND RELEASED BY PCRWRD |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM03608
Permite Description: SFR 130.1460 T21-M0026
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Ready | |
| 10/27/2022 | COT - LCBU - Framing | N/A | Not Ready | |
| 10/26/2022 | COT - RSEL - Construction Power | N/A | Not Ready | |
| 10/26/2022 | COT - RSPL - Gas Pressure Test | N/A | Not Ready | |
| 10/26/2022 | COT - RSPL - Yard Water Line | N/A | Not Ready | |
| 06/05/2023 | RSME - Mechanical Progress | N/A | Not Applicable | |
| 06/05/2023 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | |
| 06/05/2023 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 6-5-23: Install anti tip protector at range. |
| 06/05/2023 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 6-5-23: Disposer/dishwasher circuit is connected to kitchen counter receptacle circuit, and mis-labeled at panel. |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM03608
Permit Description: SFR 130.1460 T21-M0026
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2022 | COT - RSPL - Sewer | Passed | {Activity date: 06/22/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 06/22/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 06/22/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 07/01/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 07/01/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 07/01/2022 | COT - RSBU - Preslab | Passed | {Activity date: 07/01/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 07/01/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 07/01/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 07/01/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 07/01/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 08/22/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 08/22/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} | |
| 08/22/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 08/22/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} | |
| 11/30/2022 | COT - HCBU - Interior Shear Bracing | Passed | corrections were made | |
| 12/01/2022 | COT - RSPL - Yard Water Line | Passed | ||
| 12/01/2022 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 02/27/2023 | COT - BULD - SWG Clearance | Passed | clearance for Southwest Gas | |
| 06/05/2023 | RSBU - Building Final | Passed | ||
| 06/05/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
| 06/08/2023 | COT - RSPL - Plumbing Final | Passed | ||
| 06/08/2023 | COT - RSME - Mechanical Final | Passed | ||
| 06/08/2023 | COT - RSEL - Electrical Final | Passed |