Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM03373
Permit Details
Apply Date:
05/04/2022
Applicant:
Ben Smith
Description:
SFR F60A22 T22-M0028
Permit Reviews
Permit Number - T22CM03373
Permit Status: Issued
Permit Description: SFR F60A22 T22-M0028
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/14/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 07/17/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM03373
Permit Status: Issued
Permit Description: SFR F60A22 T22-M0028
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
05/04/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
07/17/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
07/17/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
07/17/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - T22CM03373
Permit Status: Issued
Permit Description: SFR F60A22 T22-M0028
Date | Description | Comments |
---|---|---|
05/04/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
05/04/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM03373
Permit Description: SFR F60A22 T22-M0028
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
06/28/2022 | COT - RSPL - Sewer | Passed | {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
07/13/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 07/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
07/13/2022 | COT - RSBU - Preslab | Passed | {Activity date: 07/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
07/13/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 07/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
07/13/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 07/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/28/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
08/11/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 08/11/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
08/11/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 08/11/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
12/20/2022 | COT - RSPL - Rough Soil | Passed | ||
12/20/2022 | COT - RSPL - Gas Pressure Test | Passed | ||
12/20/2022 | COT - LCPL - Plumbing Intermediate | Passed | ||
12/20/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
12/20/2022 | COT - RSEL - Construction Power | Passed | ||
12/20/2022 | COT - LCBU - Framing | Passed | ||
12/20/2022 | RSME - Mechanical Progress | Passed | ||
01/26/2023 | COT - HCBU - Interior Shear Bracing | Passed | ||
04/04/2023 | COT - BULD - SWG Clearance | Passed | SWG for meter only | |
04/19/2023 | COT - RSME - Mechanical Final | Passed | ||
04/19/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
04/19/2023 | COT - RSPL - Plumbing Final | Passed | ||
04/19/2023 | COT - RSEL - Electrical Final | Passed | ||
04/19/2023 | RSBU - Building Final | Passed |