Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Apply Date:
04/26/2022
Applicant:
Helen Ormsby
Description:
SFR DRHOH35F21 T21-M0043: REV 1 as-built wall location REV 2 update to Special Inspection Cert

Permit Reviews

Permit Number - T22CM03083
Permit Status: Complete
Permit Description: SFR DRHOH35F21 T21-M0043: REV 1 as-built wall location REV 2 update to Special Inspection Cert
Start Date Submittal Complete Date Status  
01/12/2023 RESIDENTIAL NEW DWELLING v.1 01/13/2023 APPROVED Review Details
03/20/2023 RESIDENTIAL NEW DWELLING v.1 03/23/2023 APPROVED Review Details
02/10/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 02/15/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T22CM03083
Permit Status: Complete
Permit Description: SFR DRHOH35F21 T21-M0043: REV 1 as-built wall location REV 2 update to Special Inspection Cert
Total Outstanding Activity Conditions - 2
Date Name
04/26/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
04/26/2022 NO FINAL UNTIL THE PUBLIC SEWER G-2018-112(P21WP00113) IS ACCEPTED AND RELEASED BY PCRWRD

Conditions

Permit Number - T22CM03083
Permit Status: Complete
Permit Description: SFR DRHOH35F21 T21-M0043: REV 1 as-built wall location REV 2 update to Special Inspection Cert
Date Description Comments
04/26/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: T22CM03083
Permite Description: SFR DRHOH35F21 T21-M0043: REV 1 as-built wall location REV 2 update to Special Inspection Cert
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Not Ready
12/12/2022 COT - RSPL - Gas Pressure Test N/A Not Ready add pressure to line.
12/12/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready add receptacles in rooms. provide DWV test. fire stop all top penetrations.
12/12/2022 COT - LCBU - Framing N/A Not Ready missing anchor bolts on edges of bottom plates.
12/12/2022 COT - LCPL - Plumbing Intermediate N/A Not Ready provide DWV test. add water to shower and tub.
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: T22CM03083
Permit Description: SFR DRHOH35F21 T21-M0043: REV 1 as-built wall location REV 2 update to Special Inspection Cert
Total Completed Inspections - 23
Date Description Inspector Results Comments
10/06/2022 COT - RSPL - Rough Soil Passed {Activity date: 10/06/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
10/14/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 10/14/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
10/14/2022 COT - RSBU - Preslab Passed {Activity date: 10/14/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
10/14/2022 COT - RSEL - Electrical Underground Passed {Activity date: 10/14/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
10/14/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 10/14/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
11/16/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
12/12/2022 COT - RSBU - Roof Nailing Passed
12/12/2022 RSME - Mechanical Progress Passed
12/13/2022 COT - RSPL - Gas Pressure Test Passed
12/13/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
12/13/2022 COT - LCBU - Framing Passed
12/14/2022 COT - LCPL - Plumbing Intermediate Passed
12/16/2022 COT - RSEL - Construction Power Passed
12/28/2022 COT - HCBU - Interior Shear Bracing Passed
01/05/2023 COT - RSPL - Sewer Passed
01/13/2023 BULD - Electrical Clearance Passed
02/27/2023 COT - BULD - SWG Clearance Passed Ok to set gas meter.
02/27/2023 COT - RSPL - Yard Water Line Passed
03/14/2023 COT - RSPL - Plumbing Final Passed
03/14/2023 RSBU - Building Final Passed
03/14/2023 COT - RSEL - Electrical Final Passed
03/14/2023 COT - RSEL - Outdoor Lighting Passed
03/14/2023 COT - RSME - Mechanical Final Passed