Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM02710
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
9779 E LYNX LAKE TR
Address NEW:
9779 E LYNX LAKE TR
Apply Date:
04/13/2022
Applicant:
Ben Smith
Description:
SFR F40J22 T22-M0022
Permit Reviews
Permit Number - T22CM02710
Permit Status: Issued
Permit Description: SFR F40J22 T22-M0022
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/13/2022 | OTHER | 05/17/2022 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T22CM02710
Permit Status: Issued
Permit Description: SFR F40J22 T22-M0022
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 04/13/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 04/13/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 04/13/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 04/13/2022 | NO FINAL UNTIL THE PUBLIC SEWER G-2020-052 IS ACCEPTED AND RELEASED BY PCRWRD |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM02710
Permite Description: SFR F40J22 T22-M0022
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2022 | FCON – OH Piping & Hydro | N/A | Not Applicable | |
| 12/16/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | maintain min 10 feet clearance from fresh air intake to vents |
| 12/16/2022 | COT - LCPL - Plumbing Intermediate | N/A | Re-inspection required | leak in DWV system |
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM02710
Permit Description: SFR F40J22 T22-M0022
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2022 | COT - RSPL - Sewer | Passed | {Activity date: 05/20/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 05/23/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 05/23/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/20/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR} | |
| 05/23/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 05/23/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} ; {Activity date: 05/20/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO 1. Remove all rocks/clods from trench 2. Support soil pipe with approved bedding material Note. Water is full in all pipes} |
|
| 06/02/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/02/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
| 06/02/2022 | COT - RSBU - Preslab | Passed | {Activity date: 06/02/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
| 06/02/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 06/02/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
| 06/03/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/02/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval missing one front} | |
| 07/15/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 07/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/07/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR} | |
| 07/15/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 07/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/07/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR Roof sheathing incomplete.} |
|
| 12/16/2022 | BULD - Electrical Clearance | Passed | TEP ECO | |
| 12/16/2022 | COT - LCBU - Framing | Passed | ||
| 12/16/2022 | COT - RSEL - Construction Power | Passed | ||
| 12/16/2022 | COT - RSPL - Gas Pressure Test | Passed | ||
| 12/19/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 12/19/2022 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 04/10/2023 | COT - BULD - SWG Clearance | Passed | SWG clearance required | |
| 04/10/2023 | COT - RSPL - Plumbing Final | Passed | ||
| 04/24/2023 | COT - RSME - Mechanical Final | Passed | ||
| 04/24/2023 | COT - FCON - Sprinkler - Final | Passed | ||
| 04/24/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
| 04/24/2023 | COT - FCON - Fire - Final | Passed | ||
| 04/25/2023 | RSBU - Building Final | Passed | ||
| 04/25/2023 | COT - RSEL - Electrical Final | Passed | ||
| 04/27/2023 | RSME - Mechanical Progress | Passed | ||
| 04/27/2023 | COT - HCBU - Interior Shear Bracing | Passed |