Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM02223
Permit Details
Apply Date:
03/29/2022
Applicant:
Description:
SFR RICHT91919 T19-M0086
Outstanding Activity Conditions
Permit Number - T22CM02223
Permit Status: Issued
Permit Description: SFR RICHT91919 T19-M0086
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
03/29/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
03/29/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
03/29/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM02223
Permit Description: SFR RICHT91919 T19-M0086
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 04/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/19/2022 | COT - RSPL - Sewer | Passed | {Activity date: 04/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/20/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 04/20/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 04/19/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO Remove all clods from trench, water test low} |
|
05/03/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 05/02/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} | |
05/03/2022 | COT - RSBU - Preslab | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 05/02/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO 1. Install property line string line. 2. Reinforcing laying in dirt 3. Ufer laying in dirt} |
|
05/03/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 05/02/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} | |
05/03/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 05/03/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 05/02/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} | |
05/13/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 05/13/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
05/13/2022 | COT - LCBU - Framing | Passed | {Activity date: 05/13/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
05/13/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 05/13/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
09/16/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO} | |
09/16/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP. TEP ECO} | |
09/16/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 09/16/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
09/30/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/30/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/26/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - not ready. Gas line needs to be re bonded. } ; {Activity date: 09/16/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE} |
|
10/05/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 10/05/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} ; {Activity date: 10/04/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR} ; {Activity date: 09/30/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Not ready. Provide blocking at register.} ; {Activity date: 09/26/2022; Status: Denied; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - denied. Per previous notes.} ; {Activity date: 09/16/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE 1. Seal penetrations in the lath 2. 2 letins in a roe max 3. Nail plate ABS 4. Romex incomplete thruout 5. Move two smoke det more than 3 feet from bathroom door 6. Replace fresh air intake duct} |
|
10/05/2022 | RSME - Mechanical Progress | Passed | {Activity date: 10/05/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} ; {Activity date: 10/04/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR} ; {Activity date: 09/30/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Not ready. Provide blocking at register.} ; {Activity date: 09/26/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - not ready. Support duct work. Provide blocking at register. } ; {Activity date: 09/16/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE} |
|
10/07/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 10/07/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by RSALDAT1 - approved} | |
02/16/2023 | COT - BULD - SWG Clearance | Passed | SWG for meter only | |
02/17/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
02/17/2023 | COT - RSME - Mechanical Final | Passed | ||
02/23/2023 | COT - RSPL - Plumbing Final | Passed | ||
02/23/2023 | RSBU - Building Final | Passed | ||
02/23/2023 | COT - RSEL - Electrical Final | Passed |