Permit: T22CM01530
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
1125 E ASCENT ST
Address NEW:
1125 E ASCENT ST
Apply Date:
03/02/2022
Applicant:
Celina Rodriguez
Description:
SFR KBME1609 T21-M0008
Outstanding Activity Conditions
Permit Number - T22CM01530
Permit Status: Issued
Permit Description: SFR KBME1609 T21-M0008
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 03/02/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 03/02/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 03/02/2022 | PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE OF FINAL STATUS. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM01530
Permite Description: SFR KBME1609 T21-M0008
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM01530
Permit Description: SFR KBME1609 T21-M0008
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 03/17/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 03/17/2022 | COT - RSPL - Sewer | Passed | {Activity date: 03/17/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 03/17/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 03/17/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 04/07/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 04/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 04/07/2022 | COT - RSBU - Preslab | Passed | {Activity date: 04/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 04/07/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 04/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 04/07/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 04/07/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 07/01/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 07/01/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/29/2022; Status: Cancelled; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Canceled by contractor } ; {Activity date: 05/06/2022; Status: Denied; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Denied. Missing to many nails and clips. STOPPED INSPECTION.} |
|
| 07/01/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 07/01/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/29/2022; Status: Cancelled; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Canceled by contractor } ; {Activity date: 05/06/2022; Status: Denied; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Denied. Missing to many nails and clips. STOPPED INSPECTION.} |
|
| 09/07/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 09/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 09/07/2022 | COT - LCBU - Framing | Passed | {Activity date: 09/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 09/07/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 09/07/2022 | RSME - Mechanical Progress | Passed | {Activity date: 09/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 09/07/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 09/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 09/13/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 09/13/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - CODE ECO} | |
| 09/13/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 09/13/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved. The TEP clearance code is ECO.} | |
| 12/13/2022 | COT - BULD - SWG Clearance | Passed | clearance for Southwest Gas | |
| 12/20/2022 | COT - RSPL - Plumbing Final | Passed | ||
| 12/20/2022 | COT - RSEL - Electrical Final | Passed | ||
| 12/20/2022 | COT - RSEL - Outdoor Lighting | Passed | ||
| 12/20/2022 | COT - RSME - Mechanical Final | Passed | ||
| 12/20/2022 | RSBU - Building Final | Passed |