Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM01225
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2385 W 40TH ST
Address NEW:
2385 W 40TH ST
Apply Date:
02/17/2022
Applicant:
Description:
NEW SFR SWC1320 T19-M0080 - C of O
Permit Reviews
Permit Number - T22CM01225
Permit Status: Complete
Permit Description: NEW SFR SWC1320 T19-M0080 - C of O
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/17/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 03/31/2022 | COMPLETED |
| 03/31/2022 | RESUBMITTAL | 04/26/2022 | COMPLETED |
| 01/27/2023 | RESIDENTIAL NEW DWELLING v.1 | 02/02/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM01225
Permit Status: Complete
Permit Description: NEW SFR SWC1320 T19-M0080 - C of O
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 01/31/2023 | Please tag and protect all saguaros on site during the construction. |
| 02/03/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. |
| 02/17/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 02/17/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Conditions
Permit Number - T22CM01225
Permit Status: Complete
Permit Description: NEW SFR SWC1320 T19-M0080 - C of O
| Date | Description | Comments |
|---|---|---|
| 02/17/2022 | PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE OF FINAL STATUS. |
Outstanding Inspections
Permit Status: Complete
Permit Number: T22CM01225
Permite Description: NEW SFR SWC1320 T19-M0080 - C of O
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2022 | COT - LCPL - Plumbing Intermediate | N/A | Canceled | {Activity date: 03/22/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
| 03/22/2022 | RSME - Mechanical Progress | N/A | Canceled | {Activity date: 03/22/2022; Status: Not Applicable; Inspector: KEN; Comment: Entered by KKARSEN1 - } |
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: T22CM01225
Permit Description: NEW SFR SWC1320 T19-M0080 - C of O
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 06/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Approved. Ok to cover progress areas.} | |
| 06/09/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/09/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved} | |
| 06/09/2022 | COT - RSBU - Preslab | Passed | {Activity date: 06/09/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved} | |
| 06/09/2022 | COT - RSPL - Sewer | Passed | {Activity date: 06/09/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, connected to existing septic tank system, okay to backfill progress areas} | |
| 06/09/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/09/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved} | |
| 06/27/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 06/27/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved} | |
| 06/27/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 06/27/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved} | |
| 07/18/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 07/18/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved} | |
| 07/18/2022 | COT - LCBU - Framing | Passed | {Activity date: 07/18/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved} | |
| 08/04/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 08/04/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - CODE ECO} | |
| 08/04/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 08/04/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, okay to backfill progress areas } |
|
| 08/04/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 08/04/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, please send ECO Clearance to TEP for the construction power} | |
| 01/09/2023 | COT - RSPL - Plumbing Final | Passed | ||
| 01/09/2023 | COT - RSEL - Electrical Final | Passed | ||
| 01/09/2023 | COT - RSME - Mechanical Final | Passed | ||
| 01/09/2023 | RSBU - Building Final | Passed | ||
| 01/09/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
| 02/06/2023 | PDSD Engineering Division Pre-Construction SITE | Passed | Contractor submitted the approved plans and changes and send it to me on my phone |