Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address NEW:
1010 N ANITA AV 01
Apply Date:
02/10/2022
Applicant:
Cyrus Moore
Description:
LOT A - building 3 duplexes on 3 different lots at 1010 N. anita, 1006 N. Anita and 1011 N. Van Alst

Permit Reviews

Permit Number - T22CM01026
Permit Status: Issued
Permit Description: LOT A - building 3 duplexes on 3 different lots at 1010 N. anita, 1006 N. Anita and 1011 N. Van Alst
Start Date Submittal Complete Date Status  
02/10/2022 3RD PARTY REVIEW - RESIDENTIAL 05/26/2022 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T22CM01026
Permit Status: Issued
Permit Description: LOT A - building 3 duplexes on 3 different lots at 1010 N. anita, 1006 N. Anita and 1011 N. Van Alst
Total Outstanding Activity Conditions - 3
Date Name
06/03/2024 Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection.
06/03/2024 Post-Installed Anchor Inspection Report is required.
06/03/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Outstanding Inspections

Permit Status: Issued
Permit Number: T22CM01026
Permite Description: LOT A - building 3 duplexes on 3 different lots at 1010 N. anita, 1006 N. Anita and 1011 N. Van Alst
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
10/31/2023 COT - RSPL - Plumbing Final N/A Re-inspection required 10/31/23: missing water hammer arrestor at dishwasher, gfci receptacle missing under sink, panel scheduled missing, prop secure whip at A/C unit, properly secure disconnect stand to roof at A/C unit, A/C condensate drain needs to be coated for up rays and be properly supported. Water heater pressure relief not terminated.
10/27/2022 RSBU - Building Final N/A Not Ready
12/12/2023 BULD - Electrical Clearance N/A Not Applicable

Completed Inspections

Permit Status: Issued
Permit Number: T22CM01026
Permit Description: LOT A - building 3 duplexes on 3 different lots at 1010 N. anita, 1006 N. Anita and 1011 N. Van Alst
Total Completed Inspections - 15
Date Description Inspector Results Comments
07/29/2022 COT - RSPL - Sewer Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved connected to HCS}
07/29/2022 COT - RSPL - Rough Soil Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved}
08/10/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 08/10/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved for dual meter location} ; {Activity date: 08/08/2022; Status: Cancelled; Inspector: DQUINN; Comment: Entered by VVERA1 - ca

Per Cyrus

}
08/10/2022 COT - RSBU - Preslab Passed {Activity date: 08/10/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved} ; {Activity date: 08/08/2022; Status: Cancelled; Inspector: DQUINN; Comment: Entered by VVERA1 - ca

Per Cyrus

}
09/01/2022 COT - RSBU - Roof Nailing Passed {Activity date: 09/01/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved. Ok to dry in roof system.}
09/07/2022 COT - LCBU - Framing Passed {Activity date: 09/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved. Ok to install intermediates.}
10/19/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 10/19/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved. Ok to drop water test in bath tubs.}
10/19/2022 RSEL - Electrical Progress Passed {Activity date: 10/19/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved. Ok to insulate and cover walls.}
10/19/2022 RSME - Mechanical Progress Passed {Activity date: 10/19/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved}
10/19/2022 COT - RSBU - Sustainability Passed {Activity date: 10/19/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved}
02/01/2023 COT - RSEL - Electrical Underground Passed Approved for underground electric conduit from dual pack meter location to unit 1 and unit 2 sub-panels, okay to backfill progress areas
11/09/2023 RSBU - Building Final Passed Approved units #1 and #2, all items were addressed
11/09/2023 COT - RSEL - Service Upgrade Passed Approved units #1 and #2
11/09/2023 COT - RSME - Mechanical Final Passed Approved units #1 and #2, all items were addressed
11/09/2023 COT - RSEL - Electrical Final Passed Approved units #1 and #2, all items were addressed

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 1026 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 1026 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PSA 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD 1026.PDF DOCUMENTS VIEW
PERMIT 1026.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
PSA.PDF DOCUMENTS VIEW