Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
02/04/2022
Applicant:
Celina Rodriguez
Description:
SFR KBHO146519 T19-M0156

Outstanding Activity Conditions

Permit Number - T22CM00892
Permit Status: Issued
Permit Description: SFR KBHO146519 T19-M0156
Total Outstanding Activity Conditions - 2
Date Name
02/04/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
02/04/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Completed Inspections

Permit Status: Issued
Permit Number: T22CM00892
Permit Description: SFR KBHO146519 T19-M0156
Total Completed Inspections - 22
Date Description Inspector Results Comments
04/20/2022 COT - RSPL - Yard Water Line Passed {Activity date: 04/20/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP}
04/20/2022 COT - RSPL - Rough Soil Passed {Activity date: 04/20/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP}
05/03/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 05/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
05/03/2022 COT - RSBU - Preslab Passed {Activity date: 05/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
05/03/2022 COT - RSEL - Electrical Underground Passed {Activity date: 05/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
05/03/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 05/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
06/01/2022 COT - RSBU - Roof Nailing Passed {Activity date: 06/01/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP}
06/01/2022 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 06/01/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - AP}
07/27/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 07/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO}
07/27/2022 COT - RSEL - Construction Power Passed {Activity date: 07/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP
TEP ECO

}
08/23/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 08/23/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP}
08/23/2022 COT - RSPL - Sewer Passed {Activity date: 08/23/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 04/20/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP}
08/30/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 08/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 08/23/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE
1. Lath incomplete.
2. Burn in line-set
3. Secure romex within 12” of box
4. Nail plate PEX in kitchen
5. Attach bathroom exhaust box to side of truss
6. Attach ladder blocking to shear wall per detail #307
7. Install all anchor bolts to shear walls per schedule}
08/30/2022 COT - LCBU - Framing Passed {Activity date: 08/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 08/23/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE}
08/30/2022 RSME - Mechanical Progress Passed {Activity date: 08/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 08/23/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE}
08/30/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 08/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP}
09/19/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 09/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP}
11/16/2022 COT - RSPL - Plumbing Final Passed SWG clearance required
11/17/2022 COT - RSEL - Electrical Final Passed
11/17/2022 COT - RSEL - Outdoor Lighting Passed
11/18/2022 RSBU - Building Final Passed
11/18/2022 COT - RSME - Mechanical Final Passed

Documents

File Name Document Type  
PERMIT.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
SITE PLAN.PDF CONSTRPLANS VIEW
SPECIAL INSPECTION.PDF DOCUMENTS VIEW