Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM00696
Permit Details
Apply Date:
01/28/2022
Applicant:
Description:
NEW SFR MODEL RICHT914 T19-M0082
Outstanding Activity Conditions
Permit Number - T22CM00696
Permit Status: Issued
Permit Description: NEW SFR MODEL RICHT914 T19-M0082
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
01/28/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/28/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM00696
Permite Description: NEW SFR MODEL RICHT914 T19-M0082
Total Outstanding Inspections - 6
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2022 | COT - RSEL - Outdoor Lighting | N/A | Canceled | Inspection Canceled |
11/04/2022 | COT - RSPL - Plumbing Final | N/A | Canceled | Inspection Canceled |
12/05/2022 | COT - RSEL - Construction Power | N/A | Not Ready | missing deadfront to electrical panel. secure UFER . |
11/04/2022 | RSPL - Plumbing Progress | N/A | Canceled | Inspection Canceled |
12/16/2022 | COT - HCBU - Interior Shear Bracing | N/A | Not Ready | missing screws on ceilings and perimeter of drywall. wrong screws in shower. non corrosive screws need to be installed. |
03/20/2023 | RSBU - Building Final | N/A | Re-inspection required | Light in owner bathroom flickers when turning on and off exhaust fan check wiring March 20th: clean back yard of construction debris and grade & clean front yard |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM00696
Permit Description: NEW SFR MODEL RICHT914 T19-M0082
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/08/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 03/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
03/08/2022 | COT - RSPL - Sewer | Passed | {Activity date: 03/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
03/08/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 03/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
04/08/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 04/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/08/2022 | COT - RSBU - Preslab | Passed | {Activity date: 04/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/07/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR Plans are not on site & the footing reinforcing is laying in the dirt} |
|
04/08/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 04/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/08/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 04/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/19/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 04/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
04/21/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 04/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/19/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO Follow detail 14/SD3c condition A on 2nd floor shear connection to truss cord. Remove all nails from top plates into bottom cords of truss.} |
|
12/12/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | corrections were made. | |
12/12/2022 | COT - LCPL - Plumbing Intermediate | Passed | corrections were made. | |
11/23/2022 | RSME - Mechanical Progress | Passed | approved | |
12/05/2022 | COT - RSPL - Gas Pressure Test | Passed | holding 15 psi | |
12/12/2022 | COT - LCBU - Framing | Passed | corrections were made. | |
12/20/2022 | COT - RSBU - Interior Shear Bracing | Passed | corrections were made | |
03/13/2023 | COT - RSME - Mechanical Final | Passed | ||
03/13/2023 | COT - BULD - SWG Clearance | Passed | SWG for meter only | |
03/13/2023 | BULD - Electrical Clearance | Passed | TEP ECO | |
03/16/2023 | COT - RSPL - Gas Final | Passed | ||
03/20/2023 | COT - RSEL - Electrical Final | Passed | ||
03/21/2023 | RSBU - Building Final | Passed |