Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T22CM00518
Permit Details
Apply Date:
01/24/2022
Applicant:
Paul Corr
Description:
SFR LENNVC351 T20-M0032
Permit Reviews
Permit Number - T22CM00518
Permit Status: Issued
Permit Description: SFR LENNVC351 T20-M0032
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/16/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/17/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM00518
Permit Status: Issued
Permit Description: SFR LENNVC351 T20-M0032
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/24/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T22CM00518
Permit Status: Issued
Permit Description: SFR LENNVC351 T20-M0032
Date | Description | Comments |
---|---|---|
01/24/2022 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
01/24/2022 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM00518
Permit Description: SFR LENNVC351 T20-M0032
Total Completed Inspections - 18
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/16/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 03/16/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
03/16/2022 | COT - RSPL - Sewer | Passed | {Activity date: 03/16/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
03/16/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 03/16/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
03/30/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 03/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
03/30/2022 | COT - RSBU - Preslab | Passed | {Activity date: 03/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
03/30/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 03/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
03/30/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 03/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
04/13/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 04/13/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} | |
04/13/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 04/13/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} | |
06/29/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 06/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - CODE ECO} | |
06/29/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 06/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved clear TEP ECO} ; {Activity date: 06/07/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR} | |
08/04/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 08/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
08/11/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 08/11/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved} ; {Activity date: 08/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - corrections required, finish exhaust fan installation, provide DWV test.} | |
08/11/2022 | COT - LCBU - Framing | Passed | {Activity date: 08/11/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved} ; {Activity date: 08/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - corrections required, seal all top plate penetrations.} | |
08/11/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 08/11/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved} ; {Activity date: 08/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - corrections required, DWV test required.} | |
08/11/2022 | RSME - Mechanical Progress | Passed | {Activity date: 08/11/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - approved} ; {Activity date: 08/04/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Ready} | |
08/31/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 08/31/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 08/30/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - DE Garage shear wall not fastened per schedule. Other shear walls exceed the max spacing. } |
|
10/18/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 10/18/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - CODE GAS} |