Conditions

Permit Number - T22CM00457
Permit Status: Complete
Permit Description: SFR RICHT25B T21-M0016
Date Description Comments
01/20/2022 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
01/20/2022 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
01/20/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: T22CM00457
Permite Description: SFR RICHT25B T21-M0016
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
10/27/2022 COT - RSME - Mechanical Final N/A Not Ready
10/27/2022 RSBU - Building Final N/A Not Ready
10/27/2022 COT - RSEL - Outdoor Lighting N/A Not Ready
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready
10/27/2022 COT - RSEL - Electrical Final N/A Not Ready
10/26/2022 COT - RSBU - Roof Nailing N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: T22CM00457
Permit Description: SFR RICHT25B T21-M0016
Total Completed Inspections - 16
Date Description Inspector Results Comments
02/08/2022 COT - RSPL - Yard Water Line Passed {Activity date: 02/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
02/08/2022 COT - RSPL - Sewer Passed {Activity date: 02/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
02/08/2022 COT - RSPL - Rough Soil Passed {Activity date: 02/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
02/15/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 02/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
02/15/2022 COT - RSBU - Preslab Passed {Activity date: 02/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
02/15/2022 COT - RSEL - Electrical Underground Passed {Activity date: 02/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - -AP

Field

12-2

Texted ETA at 9:47}
02/15/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 02/15/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP

CONTACTS:

RICHMOND AMERICAN HOMES ** APA *** - 520-229-5432 ,(520) 229-5441

CONTRACTOR: RICHMOND AMERICAN HOMES ** APA *** (520-904-5039- (520) 229-5441),

No Other Contact listed}
03/04/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 03/04/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved}
08/02/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 08/02/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved}
08/02/2022 COT - LCBU - Framing Passed {Activity date: 08/02/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved}
08/02/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 08/02/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved}
08/02/2022 RSME - Mechanical Progress Passed {Activity date: 08/02/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved}
08/02/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 08/02/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved}
08/12/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 08/12/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO}
08/12/2022 COT - RSEL - Construction Power Passed {Activity date: 08/12/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP
TEP ECO}
08/17/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 08/17/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Approved}

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
C OF O 2024 MASS-UPLOAD.DOC DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
SIC 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
SITE PLAN 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
C OF O.DOC DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
SIC.PDF DOCUMENTS VIEW
SITE PLAN.PDF DOCUMENTS VIEW