Permit: T22CM00440
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
8831 E STONE MEADOW CI
Address NEW:
8831 E STONE MEADOW CI
Apply Date:
01/20/2022
Applicant:
KB HOME
Description:
SFR Model 1383130 T20-M0063
Contractors:
- KB HOME OF TUCSON *APA*
Outstanding Activity Conditions
Permit Number - T22CM00440
Permit Status: Final
Permit Description: SFR Model 1383130 T20-M0063
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/20/2022 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T22CM00440
Permit Description: SFR Model 1383130 T20-M0063
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2022 | PLUMBING - YARD WTR LINE/TEST | ESTEVENS | Approved | Approved |
| 02/18/2022 | PLUMBING - SEWER HCS CONNECT | ESTEVENS | Approved | Approved |
| 02/18/2022 | PLUMBING - ROUGH, SOIL | ESTEVENS | Approved | Approved |
| 04/12/2022 | ELECTRIC - UNDERGROUND | WGALLAGHER | Approved | APPROVED |
| 04/12/2022 | ELECTRIC - UFER | WGALLAGHER | Approved | APPROVED |
| 04/12/2022 | BUILDING PRE-SLAB | WGALLAGHER | Approved | APPROVED |
| 04/12/2022 | EXCAVATION/LAYOUT REBAR & ZON | WGALLAGHER | Approved | APPROVED |
| 04/25/2022 | ROOF NAILING | RCHANDLER | Approved | AP |
| 04/25/2022 | EXT METAL CLIPS/EXT SHEATHING | RCHANDLER | Approved | AP |
| 06/30/2022 | MECHANICAL - INTERMEDIATE | TLUNDBERG | Approved | AP |
| 06/30/2022 | PLUMBING - GAS PRESSURE TEST | TLUNDBERG | Approved | AP |
| 06/30/2022 | PLUMBING - INTERMEDIATE | TLUNDBERG | Approved | AP |
| 06/30/2022 | ELECTRIC - INTERMEDIATE | TLUNDBERG | Approved | AP |
| 06/30/2022 | RESIDENTIAL INTERMEDIATE | TLUNDBERG | Approved | AP |
| 06/30/2022 | FRAMING | TLUNDBERG | Approved | AP |
| 07/07/2022 | TEP CLEARANCE - PM | ESTEVENS | Approved | CODE ECO |
| 07/07/2022 | ELECTRIC - CABLE DROP | ESTEVENS | Approved | approved. The TEP clearance code is ECO. |
| 08/02/2022 | SHEET ROCK NAILING | RCHANDLER | Approved | AP |
| 10/07/2022 | GAS CLEARANCE | TLUNDBERG | Approved | CODE GAS |
| 10/07/2022 | PLUMBING - FINAL | TLUNDBERG | Approved | AP SWG clearance required |
| 10/17/2022 | OUTDOOR LIGHTING FINAL | TLUNDBERG | Approved | AP |
| 10/17/2022 | MECHANICAL - FINAL | TLUNDBERG | Approved | AP |
| 10/17/2022 | STUCCO MESH | TLUNDBERG | Approved | 1090.AP |
| 10/17/2022 | U VALUE FOR WINDOW | TLUNDBERG | Approved | 1090.AP |
| 10/17/2022 | BUILDING - FINAL | TLUNDBERG | Approved | AP |
| 10/17/2022 | ELECTRIC - FINAL | TLUNDBERG | Approved | AP |
| 10/17/2022 | PLUMBING - PRE SLAB | TLUNDBERG | Approved | 1090.AP |
| 10/17/2022 | PLUMBING - GAS PRESS TEST FNL | TLUNDBERG | Approved | 1090.AP |
| 10/17/2022 | SITE - SEWER | TLUNDBERG | Approved | 1090.AP |