Permit Details
Status:
Final
Type:
Barricade and Excavation
Apply Date:
07/07/2021
Applicant:
COX COMMUNICATIONS
Description:
Starting in the alley behind 2424 N Park ave at TEP pole, Overlash going East 470' riser down pole, Place a 2x3x3 pothole place new vault , from vault trench bore South 150' installing .48 ct fiber and 2" conduit continue East 95' South 30' place a 3x3x3 pothole for new vault continue East 3' place another 3x3x3 pothole and vault.
Address changed from 2320 N Fremont Av on application to 1101 E Grant Rd closest to SWF Pole, fiber directly associated with Small Wireless Facility.
Proof of notification is required at the time of the preconstruction meeting.
INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED.
ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. AND MUST BE A MINIMUM OF 18-FT HIGH WHEN CROSSING INTERSECTIONS, PAVEMENT AND ALLEYS.
PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION.
POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. *MORATORIUM REQUIREMENTS WILL BE CONVEYED IN THE FIELD BY THE INSPECTOR.*
BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.)
ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE.
REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES.
REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE.
GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION.
MAINTAIN PEDESTRIAN ACCESS
MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS.
ADDITIONAL NOTES: THE FRONTAGE RD OF WEST BOUND GRANT, WHERE THERE WILL BE BORING IS UNDER MORATORIUM. IF CUT, THE INSPECTOR WILL PROVIDE MORATORIUM PATCHING REQUIREMENTS.
ADDITIONAL NOTES: IF WEEKEND WORK IS INTENDED, CONTACT THE INSPECTION STAFF 48 HOURS PRIOR: DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813
10/18/2021 - PLAN ADD/CHANGE - R2
TCP has a changed - additional TCP page was added.
Scope of work change from: Starting in the alley behind 2424 N Park ave at TEP pole, Overlash going East 470' riser down pole, Place a 2x3x3 pothole place new vault , from vault trench/ bore S/E 240' installing .48 ct. fiber and 2" conduit place a 3x3x3 pothole for new vault continue North T/B 3' North to connect existing meet vault.
PRJ202265-1