Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Details
Status:
Final
Type:
Barricade and Excavation
Apply Date:
01/25/2021
Applicant:
ETCHART'S LAKESIDE PLUMBING INC
Description:
REPLACE UP TO 30 FT OF EXISTING 4" CLAY SEWER PIPE WITH NEW 4" ABS PIPE. NEED TO CUT/REPLACE UP TO 34 SQ FT OF ASPHALT FOR ACCESS.
EMERGENCY PERMIT - WITHOUT USE OF ANY FACILITIES
RESIDENT NOTIFICATION LETTER IS REQUIRED WHEN IMPACTING RESIDENTIAL AREA.
INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED.
PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION.
POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH.
BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.)
ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE.
REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE.
GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION.
MAINTAIN PEDESTRIAN ACCESS.
Documents
File Name |
Document Type |
|
T21RW00373.PDF |
ROW-RIGHT OF WAY |
VIEW
|